DRUM UNIT
June 30, 1998
[A]
[B]
A229R553.WMF
7. Remove the wire cleaner [A] (1 snap ring).
8. Install the wire cleaner and the charge corona wire.
NOTE: Locate the joint part [B] of the wire in the rear end block as shown.
After installing new wires, reset SP 2-001-1 and 2-001-4 (corona voltages) to the
defaults. Then do SP 2-962 (process control initialization).
6-38