OUTPUT TRAY (A814)
June 30, 1998
3.7.2 OUTPUT TRAY INSTALLATION PROCEDURE
[C]
[B]
[A]
A814I502.WMF
A814I501.WMF
[D]
A814I500.WMF
1. Remove the left cover [A] (2 screws).
2. Attach the sensor feeler [B] to the feeler securing bracket [C], and install it in
the copier as shown (1 screw).
3. Reinstall the left cover and install the output tray [D] as shown.