SpectraLink 6300 MCU: T1 Remote Module Installation: SpectraLink 6000 System

Connect Power to Shelves

Install Cards

20
To attach the shelves to the wall:
1. Remove all cards from the shelf. Do not mount the shelf with
cards installed.
Cards contain components that may be damaged by electrostatic
discharge. Before handling any of the cards, attach the grounding
strap (included in the Administration Kit) to your wrist, and attach
the other end of the strap to ground. Handle cards only by their
edges. Do not touch connector contact areas. Do not lift cards by
any of the components. Do not lay cards down on their component
sides. When laying a card down, place it component side up, on top
of the anti-static bag in which it was shipped.
2. Position the MCS300 so that the six mounting screws are aligned
with the six keyhole openings in the back of the shelf.
3. Slide the shelf down onto the screws to lock the shelf into place.
Check that all six screws are properly locked.
4. Tighten all six screws fully.
Do not install cards until power is connected.
Polycom recommends that a licensed electrician install the -48V DC
power supply and connect power to the shelves.
See SpectraLink 6300 MCU: Installation - Connect Power to Shelves, for
more information.
The shelf diagram below shows a fully loaded Expansion Shelf. Any
type of Interface Module can be installed in slots 3 through 12.