Connecting the RMX 4000 to the Power Sources

The size of the protective earthing conductor & cable should be a minimum of
10AWG.
Connect the following power cables to the RMX 4000 back panel:
AC Power Supply connections:
1
Insert power cables to each of the three AC Power Entry Modules
(PEMs).
Figure 2-2
RMX 4000 Rear Panel View with AC Power
DC Power Supply connections:
1
On the DC Power Rail Modules set the two circuit breakers to OFF.
Two types of circuit breakers can be installed on the DC Power Rail Module
(PRM). For more information, see the RMX 4000 Hardware Guide.
2
Ensure that the cables from the Main that supplies electricity to the
DC power units are OFF or disconnected.
Polycom RMX 1500/2000/4000 Getting Started Guide
Power Cables
2-15