Fix the selector lever (99) on the selector valve on the
pump (80). (refer to fig. 5)

13.3 Before the commissioning

Before the first use, please fix the machine to the floor by anchor bole. It must be ensured that
the standing surface of the machine site is firm and horizontal, and that sufficient lighting is pro-
vided for.
Clean the machine thoroughly
Before first use of this product, pour a teaspoon of good quality, air tool lubricant into the air
supply inlet of the lift control valve, connect to air supply to air supply and operate for 3 seconds
to evenly distribute lubricant.

13.3.1 Purge away air from the hydraulic system

Manual operation system: open the release valve (50) by turning it counterclockwise. Pump sev-
eral full stokes to eliminate any air in the system.

13.3.2 Air operating system

open the release valve (50) by turning it counterclockwise. Connect the quick coupler-male into
the air supply hose quick coupler-female, then turn on the air valve(52) letting the pump work for
several times to eliminate any air in the system.
Check all parts and conditions, if there is any part broken, stop using it and contact your supplier
immediately