Troubleshooting - Holzmann WP50H User Manual

Table of Contents

Advertisement

16 TROUBLESHOOTING

Trouble
The pump is working, while
the ram can't work
When open release valve, the
ram can't reset
manual normal, while ram
can't work
the sound from air motor, but
ram can't work
the ram can't fully work
The air motor can't work
Oil leaking
HOLZMANN Maschinen Austria
Possible cause
the oil pipe loosed the ram is
leaking
the oil pipe loosed
no enough space in pump
the ram become invalid
release
closed
air in system
release
closed
air in system
the oil is not enough
air press is not enough and
overload the capacity
air motor is broken
seal kits broken
screw parts loosed
www.holzmann-maschinen.at
valve
not
complete
valve
not
complete
Dílenský lis / shop press
Solution
checking the connecting situ-
ation of oil pipes replace the
oil seals
checking the connecting situ-
ation of oil pipes
open the exhaust valve
replace the ram
check the release valve
purge away the air according
to manual
check the release valve
purge away the air according
to manual
add oil
check the air press and ca-
pacity
Replace the air motor
replace the seal kits
Tighten the screw parts
WP 50H - WP 75H - WP 100