Figure 4-2 Pipe Mounting - Siemens SITRANS F Series Operating Instructions Manual

Ultrasonic flowmeter
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Installing/Mounting
4.4 Mounting the Transmitter
Mounting the Enclosure
1. Loosen the Enclosure cover screws and open the cover to reveal the mounting screw
2. Mark and drill four holes in the mounting surface for the four #8 screws (supplied).
3. Fasten with a long flat-blade screwdriver.
Pipe Mounting
For installation on 2-inch standpipe use Pipe Mounting Kit CQO:1012NMB-1 (optional - see
catalog). See figure below.
Figure 4-2
16
holes.
Mounting Plate
2 1/4" (57.1mm) to 2 3/8" (60.3mm) O.D
standpipe
Cable Entry Ports
Pipe Mounting
Mounting Hardware (see table below)
U-Bolt Assembly (see table below)
Operating Instructions, 02/2012, A5E03086487-05
FST020 IP65 NEMA 4X