Pulse Out Setup
The pulse output programming setup is accessed in the [I/O Data Control] menu.
1. From the [Single Channel] menu press the <Right Arrow> key and scroll down to [I/O
2. Press the <Right Arrow> key and scroll down to [Pulse Out Setup].
3. Press the <Right Arrow> key to [PGEN] (default setting) for frequency pulses/unit volume.
4. To choose Totalizer pulses, press the <Right Arrow> key and then the <Down Arrow>
5. Press <ENTER> to save selection.
6. To set the frequency span, press the <Left Arrow> twice to access the [I/O Data Control]
7. Press the <right Arrow> to select [Span Data].
8. Press the <Right Arrow> key to select [PGEN P/GAL]. Press the <Right Arrow> key
FST020 IP65 NEMA 4X
Operating Instructions, 02/2012, A5E03086487-05
Data Control].
key as needed to select [Pos Total] or [Neg Total] for single pulses per volume unit.
menu and then scroll up to the [Span/Set/Cal] menu.
Note
The volumetric units (e.g. gallons, liters, etc.) must be selected in the [Flow/Total Units]
menu. The units in the following example are GAL (US).
again.
Functions
7.8 Pulse Out Setup