Figure 5-21 Direct Mount 180° Opposed With Mounting Tracks - Siemens SITRANS F Series Operating Instructions Manual

Ultrasonic flowmeter
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Connecting
5.4 Installing the Sensor
The Direct Mount configuration uses a set of two track rail assemblies; one for each sensor,
installed 180° apart on the pipe. The set includes:
● Reflect Mode Track Assembly - This track rail includes the Tension Screw and REF hole
● Direct Mode Track Assembly - This track rail has number index holes for inserting an
Note
A pin will be inserted into the hole designated by the Number Index on the Direct Mode
track rail to position one of the sensors (see
50
to position one sensor.
index pin to position the other sensor.
To SITRANS F Transmitter
1012CNF Series Cable
Mounting Strap Guide
Sensor Clamp
1011NPS Series Sensor Upstream
1012TN Series Mounting Track
Figure 5-21
Direct Mount 180° opposed with Mounting Tracks
in figure below).
1011NPS Series Sensor Downstream
Flow direction
1012TN Series Mounting Track
REF Hole Index Pin
Ultrasonic Couplant
Pipe
Operating Instructions, 02/2012, A5E03086487-05