EMC Connectrix EC-1100 System User Manual page 187

Table of Contents

Advertisement

Connect Clients
and Connectrix
Manager Server
a. At the navigation control panel, select the New Product option
from the Configure icon. This displays the New Product
dialog box.
b. Type the first ED-1032's IP address in the Network Address
field and select ED-1032 from the Product Type list, then click
OK. The ED-1032 is defined and the corresponding icon
appears at the Product View.
A grey square appears behind the ED-1032 icon because the
Connectrix Manager server and ED-1032 are not communicating and
the status is unknown.
c. Repeat this procedure for all affected ED-1032s.
2. Determine the IP address of the Connectrix Manager server. Refer
to step 1 under Configuring the Client on page E-4 for instructions,
then return here. This IP address is required by all clients to log
into the Connectrix Manager server.
Establish an Ethernet connection between the clients and Connectrix
Manager server, and log into all clients:
1. Connect the 24-port Ethernet hubs in all affected Connectrix
cabinets (up to four cabinets) to each other:
a. Connect one end of an RJ-45 Ethernet patch cable to port 24 of
the Ethernet hub in the Connectrix cabinet that contains the
master Connectrix Manager service processor. Using a pencil
or other pointed instrument, set the medium-dependent
interface (MDI) switch on the hub to MDI (in).
b. Connect the other end of the patch cable to port 12x of the
Ethernet hub in the second Connectrix cabinet (with the
service processor configured as a client).
c. Repeat steps a and b for each cascaded Ethernet hub.
d. Wait approximately five minutes for the Ethernet link to be
established, then inspect the Product View at the Connectrix
Manager server. Ensure all ED-1032 icons appear with a green
circle as the background, indicating the ED-1032s are defined
and communicating with the EMC Connectrix Manager
application. If a problem is indicated, contact EMC Customer
Support.