Page 2
Trademark Information , EMC, CLARiiON, and Navisphere are registered trademarks and Access Logix, Application Transparent Failover, ControlCenter, EMC Enterprise Storage, The Enterprise Storage Company, The EMC Effect, FLARE, PowerPath, MirrorView, and SnapView are trademarks of EMC Corporation. All other trademarks used herein are the property of their respective owners.
Page 3
This product complies with EN55022, CISPR22 and AS/NZS 3548 Class A. This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EMC CX200-Series DPE2 Hardware Reference...
Addressing Requirements ............2-3 Disk Requirements ..............2-3 Installing a DPE2 in a Cabinet ............2-4 Warnings and Recommendations: ......... 2-4 Setting Up an Installed CX200-Series DPE2......... 2-5 Setting Enclosure Addresses ........... 2-5 Making Power Connections ............ 2-6 Making Back End Connections..........2-10 Connecting the CX200-Series DPE2 to the External Environment................
Page 6
DPE2 Powerup and Initialization..........2-14 CX200-Series Powerdown ............2-15 Turning Off the Power ............2-15 Chapter 3 Servicing and Upgrading a CX200-Series DPE2 Monitoring CX200-Series Status ............ 3-2 Handling FRUs ................3-5 Power Issues and FRUs ............3-5 Avoiding Electrostatic Discharge (ESD) Damage ....3-6 Emergency Procedures (Without an ESD Kit)......
Page 7
Power Supply/System Cooling Module ..........1-10 1-10 Standby Power Supply ................1-10 CX200-Series Enclosure Address Switch (CX200 Shown) ...... 2-6 ac Line Cord and the Power Switch (CX200 Shown) ......2-7 Connecting CX200 Power Cords ..............2-7 Connecting the Standby Power Supply to SP A ........2-8 CX200 Power Connections ................
Page 8
3-16 Plugging in the Power Cord and Turning on Power (CX200 Shown) 3-21 CX200 SPS ...................... 4-2 SPS Installation, Front and Back Views ............. 4-4 Typical SPS Self-Discharge Levels at Different Storage Temperatures A-9 viii EMC CX200-Series DPE2 Hardware Reference...
Preface This manual explains how to install an EMC CX200 or CX200LC 2-gigabit disk processor enclosure (DPE2), and how to replace field-replaceable units (FRUs). It is intended for system administrators and other qualified technical personnel. How This Manual Is Organized Chapter 1 Introduces the CX200-Series DPE2 components.
Page 10
40U Cabinet Setup Guide (P/N 014003099) Site Preparation and Unpacking Guide for the 40U Cabinet (P/N 014003100) EMC Rails and Enclosures Installation Guide for 19-Inch NEMA Cabinets (P/N 014003082) EMC Storage Systems CX200-Series Initialization Guide (P/N 014003117) EMC 2-Gigabit Disk Enclosure (DAE2) Setup Guide (P/N 014003104)
Page 11
A danger notice contains information essential to avoid a hazard that will cause severe personal injury, death, or substantial property damage if you ignore the warning. EMC uses the following type style conventions in this guide: This Indicates text (including punctuation) that you type...
Page 12
Follow the voice menu prompts to open a service call, then select CLARiiON Product Support. Sales and Customer For the list of EMC sales locations, please access the EMC home page Service Contacts http://www.emc.com/contact/ For additional information on the EMC products and services...
Das Geraet hat mehr als eine Anschlussleitung. Zur Vermeidung der Gefahr eines elektrischen Schlages sind vor dem öffnen beide Anschlussleitungen vom Netz zu trennen. STROMSTREUVERLUST: Gerät muss geerdet werden, bevor es am Stromnetz angeschlossen wird. xiii EMC CX200-Series DPE2 Hardware Reference...
Page 14
Keep all paperwork, including incident reports, up to date, complete, and accurate. Static Precautions EMC incorporates state-of-the-art technology in its designs, including the use of LSI and VLSI components. These chips are very susceptible to damage caused by static discharge and need to be handled accordingly.
About the CX200-Series DPE2 This chapter describes the CX200 and CX200LC 2-gigabit disk processor enclosures (DPE2). Major topics include Overview .....................1-2 CX200-Series Components..............1-3 About the CX200-Series DPE2...
About the CX200-Series DPE2 Overview The Model CX200-Series of 2-gigabit disk processor enclosures (DPE2), shown in Figure 1-1, are intelligent, high-performance, high-capacity disk-array storage systems that use a Fibre Channel Arbitrated Loop (FC-AL) or fabric as their interconnect interface. Each enclosure is only 3U (5.25 inches) high, but can include 15 hard disk drives.
About the CX200-Series DPE2 You can place the DAE2 in the same cabinet as the CX200, or in a separate cabinet. The CX200-Series systems connect to the external Fibre Channel environment using small form factor SFF LC optical transceivers on the storage processor. High-availability features are standard.
Fault LED Power LED (Amber) (Green) Disk Activity Fault LED (Amber) (Green) EMC2166 CX200 DPE2 Front LED Display Figure 1-2 Figure 1-3 shows the DPE2 components visible from the rear of the cabinet. EMC CX200-Series DPE2 Hardware Reference...
CX200LC DPE2 Rear View Figure 1-4 As shown in Figure 1-5, an enclosure ID, or enclosure address, switch is located between the power/cooling modules at the rear of the disk enclosure. The enclosure address for the CX200-Series DPE2 is always 0. CX200-Series Components...
Switch EMC2462 CX200 DPE2 Enclosure Address Switch/Indicator Figure 1-5 The CX200-Series status lights are described in Chapter 3, Servicing and Upgrading a CX200-Series DPE2. Midplane The midplane distributes power and signals to all the enclosure components. All FRUs plug directly into midplane connectors.
(Green) (Amber) Connector Serial Port Serial Port Factory Use FE A FE B Power Only Front-end (Green) Host Connectors EMC2463 Figure 1-7 CX200 Storage Processor The CX200-Series status lights are described in Monitoring CX200-Series Status in Chapter 3. CX200-Series Components...
The disk drives are 3.5-inch (8.75 cm) by 1.0-inch (2.54 cm), 12-Volt, Fibre Channel drives that conform to the following standards: SFF-8045 SCSI Enclosure Services (SES) portion of the SCSI 3 Standard FC-AL FC-AL Private Loop Direct Attach (PLDA) Profile 2-Gbit Fibre Channel interface EMC CX200-Series DPE2 Hardware Reference...
The status lights are described in Monitoring CX200-Series Status in Chapter 3. Figure 1-9 shows a rear view of a CX200 power/cooling module; note that a CX200LC blower and power/cooling modules are externally identical except the blower module includes none of the power switch, connector, or LED components.
Module A Interface (Green) On Battery (Amber) Replace Power Fault Battery Switch Power Connector (Amber) (Amber) EMC2464 Standby Power Supply Figure 1-10 See Chapter 4, The Standby Power Supply (SPS), for detailed information about SPSs. 1-10 EMC CX200-Series DPE2 Hardware Reference...
Installing a CX200-Series DPE2 This chapter describes the CX200-Series DPE2 installation requirements and procedures. Major topics include Requirements..................2-2 Installing a DPE2 in a Cabinet............2-4 Setting Up an Installed CX200-Series DPE2........2-5 DPE2 Powerup and Initialization ..........2-14 CX200-Series Powerdown...............2-15 Installing a CX200-Series DPE2...
Appendix A. The site must have air conditioning of the correct size and placement to maintain the specified ambient temperature range. The air conditioning must be able to handle the BTU requirements of the CX200-Series DPE2 and any additional disk enclosure. Cabling...
(EA) that identifies the enclosure and determines disk module addresses. The CX200-Series DPE2 has a fixed EA of 0, which you should not change. The standard CX200 supports one Fibre Channel loop and a maximum of two disk enclosures (including the CX200 DPE2 itself).
CX200-Series DPE2s mount inside a cabinet on two L-shaped mounting rails connected to the cabinet’s vertical channels. If you need to install a cabinet or CX200-Series chassis, refer to one of the following manuals: Installing the cabinet itself is explained in the cabinet installation manual shipped with the cabinet.
The EA can range from 0 through 7, though we recommend that you number them consecutively from 0. The CX200-Series DPE2 is always enclosure 0. An additional DAE2 disk enclosure is usually numbered 1, reflecting its position on the Fibre Channel loop (bus) connecting the array.
See Figure 2-1 as necessary. Enclosure Address Switch EMC2462 CX200-Series Enclosure Address Switch (CX200 Shown) Figure 2-1 Making Power 1. Make sure the power switches are in the off position, and then Connections plug an ac line cord into each power supply/cooling module. See Figure 2-2.
PS B and PS A to the same SPS. Refer to Figure 2-3. Power Power Supply B Supply A (PS B) (PS A) SPS A EMC2466 Connecting CX200 Power Cords Figure 2-3 Setting Up an Installed CX200-Series DPE2...
A to the closest power strip. • Skip the remaining steps in this section, and proceed with Connecting the CX200-Series DPE2 to the External Environment on page 2-11. 3. Connect storage processor A to the serial port on the standby power supply, as shown in Figure 2-4.
Installing a CX200-Series DPE2 Circuit Circuit Breaker Breaker Power/ Cooling Module A Power/ DAE2 Cooling Module B SP A SP B 240 V 240 V EMC2483 CX200 Power Connections Figure 2-5 Setting Up an Installed CX200-Series DPE2...
The two devices support a redundant loop 0. Note that the CX200 connects to the Primary disk enclosure connectors. LCC B LCC A EA1/Loop 0 EA0/Loop 0 Loop 0 Loop 0 EMC2470 Cabling a CX200 and Disk Enclosure Together Figure 2-7 2-10 EMC CX200-Series DPE2 Hardware Reference...
Installing a CX200-Series DPE2 Connecting the CX200-Series DPE2 to the External Environment When working with optical cables, observe the following precautions: Keep the covers on all optical cables and optical connectors until you are ready to insert the cables. The covers protect the cables and connectors, and prevent foreign particles, such as dust, from entering and affecting the connection.
Figure 2-8 3. Plug the other end of the FE A fibre-optic cable into the host bus adapter (HBA) or switch port. CX200-Series systems do not support MirrorView™ or SnapView™ software applications, external hubs, or daisy-chained arrays. Making Before you connect your system to a management Local Area Management LAN Network, refer to the Navisphere 6.X Release Notes for the version of...
Connect each SP to the LAN from which you will run Navisphere management, as shown in Figure 2-9 or Figure 2-10. EMC2472 Connecting the CX200 to a Shared LAN Figure 2-9 EMC2674 Connecting the CX200 to a Local Management Client Figure 2-10 2-13 Setting Up an Installed CX200-Series DPE2...
0 to 84 seconds. The slots use the same delays when you insert a drive while the system is powered up. The CX200-Series hardware monitor (FRU monitor) resets and begins its control loop. The port bypass circuits enter the states indicated by their associated drives.
EA while power is on. For instructions on how to initialize your system after its first powerup, refer to the EMC Storage Systems CX200-Series Initialization Guide and the EMC Installation Roadmap for CX-Series and FC-Series Storage Systems.
Breaker Breaker Power Switch Power DAE2 Switch Power/ Power/ DAE2 Cooling Cooling Module B Module A SP A SP B 240 V 240 V SPS Power Switch EMC2484 Powering Down (CX200 Shown) Figure 2-11 2-16 EMC CX200-Series DPE2 Hardware Reference...
Page 41
Installing a CX200-Series DPE2 CAUTION Never shut off the power supply/cooling modules to shut down a CX200 power supply that is connected to an SPS. Bypassing the SPS in that manner prevents the system from saving write cache data to the vault drives, and results in data loss. You will lose access...
Page 43
Field-Replaceable Units (FRUs), and replace or add a FRU. Topics are Monitoring CX200-Series Status ............3-2 Handling FRUs...................3-5 Replacing or Adding a Disk Module ..........3-9 Replacing a Storage Processor (SP) ..........3-15 Replacing a Power Supply/System Cooling Module....3-18 Servicing and Upgrading a CX200-Series DPE2...
Servicing and Upgrading a CX200-Series DPE2 Monitoring CX200-Series Status Status lights on the CX200/CX200LC and its FRUs indicate error conditions. These lights are visible outside the enclosure. Some lights are visible from the front, and the others from the back. Figures 3-1 through 3-4 and Tables 3-1 through 3-2 describe the status lights.
Disk Fault 1 per disk module Amber On when the disk module is faulty, or as an indication to remove the drive. Figure 3-2 shows the enclosure address switch. In CX200-Series configurations, the enclosure address will be 0; a subsequent DAE2 disk enclosure on that loop will use an incremental address (1).
Servicing and Upgrading a CX200-Series DPE2 Blower Fault Latch Power Power Fault (Amber) (Green) EMC2230 (Amber) Power Supply/Cooling Module Status Indicators Figure 3-3 Figure 3-4 shows the status LEDs for the SP. FE A FE B Link Active Link Active...
FRUs. Power Issues and The CX200-Series DPE2 is designed to always be powered up and to FRUs be hot repairable. Its front bezel should be attached and each of its compartments should contain a FRU or filler panel to ensure EMI compliance and proper air flow over the FRUs.
CX200-Series DPE2. If you need to power down a CX200-Series system, first shut down the storage processors (refer to your Navisphere Manager Administrator’s Guide), and then shut off power to the SPS, if you...
Servicing and Upgrading a CX200-Series DPE2 Do not remove replacement or upgrade FRUs from their antistatic packaging until you are ready to install them. Gather together the ESD kit and all other materials you will need before you service an enclosure. Once servicing begins, you should avoid moving away from the work site;...
Servicing and Upgrading a CX200-Series DPE2 Precautions When Use the precautions listed below when you remove, handle, or store Removing, FRUs. Installing, or Storing Do not remove a faulty FRU until you have a replacement FRUs available. Handle a FRU only when using an ESD wristband as follows:...
(bytes per sector) and the same capacity (size and speed) as the other modules in the enclosure. Before adding more disks to your DPE2, refer to the EMC Storage Systems CX200-Series Configuration Planning Guide, which contains guidelines for creating RAID groups with disks of varying sizes and speeds.
Servicing and Upgrading a CX200-Series DPE2 Unlocking and Removing the Front Bezel Refer to Figure 3-5 as you follow these steps to remove the front bezel and gain access to the disk modules. 1. Insert the key that shipped with your enclosure into the bezel lock, and turn it to release the lock.
Servicing and Upgrading a CX200-Series DPE2 Removing a Disk Filler Module Locate the slot where you want to install the disk module, and remove the filler module, as shown in Figure 3-6. EMC2210 Figure 3-6 Removing a Disk Filler Module Skip to the disk installation procedure (page 3-12) to install the add-on disk in the slot you just emptied.
Servicing and Upgrading a CX200-Series DPE2 Generally, you should not remove a disk module unless its amber fault light is on. See Table 3-1 1. Attach an ESD wristband to your wrist and the enclosure (see the precautions on page 3-7 and page 3-8).
Servicing and Upgrading a CX200-Series DPE2 EMC2211 Figure 3-8 Installing a Disk or Filler Module The disk module’s Active light flashes to reflect the disk’s spin-up sequence. 4. Remove and store the ESD wristband and continue to the next section to install the front bezel.
Servicing and Upgrading a CX200-Series DPE2 Installing and Locking the Front Bezel Refer to Figure 3-9 as you do the following: 1. Align the bezel with the disk enclosure. 2. Gently push the bezel into place on the cabinet until it latches.
Servicing and Upgrading a CX200-Series DPE2 Replacing a Storage Processor (SP) CAUTION Handle an SP gently and use an ESD wristband. Do not remove a faulty SP until you have a replacement module available. A CX200 disk enclosure must have at least one SP installed while it is powered up.
The SP Power light turns on. 2. Turn the latch clockwise to secure the module. The CX200-Series SP latch holds the module in an established position. It does not pull or otherwise help to seat the SP. 3. Reattach the cables to the same connectors from which you removed them.
Servicing and Upgrading a CX200-Series DPE2 LCC B LCC A EA1/Loop 0 EA0/Loop 0 Loop 0 Loop 0 EMC2470 Connecting SPs and Disk Enclosures Together with Copper Cable Figure 3-12 3-17 Replacing a Storage Processor (SP)
Servicing and Upgrading a CX200-Series DPE2 Replacing a Power Supply/System Cooling Module This section explains how to replace a power supply/system cooling module, and a CX200LC blower module. CAUTION Handle the modules gently and use an ESD wristband. Do not remove a power/cooling or blower module until you have a replacement module available.
Servicing and Upgrading a CX200-Series DPE2 Power Switch EMC2478 Turning Off a Supply’s Power and Unplugging Its ac Power Cord Figure 3-13 2. Turn the latch counterclockwise to release the module, and then remove the power/cooling or blower module as shown in Figure 3-14.
Servicing and Upgrading a CX200-Series DPE2 Installing a Power Supply/System Cooling Module or Blower Module 1. Gently insert the new module into the enclosure, as shown in Figure 3-15. Be sure the module is completely seated. Latch EMC2480 Installing a Power/Cooling or Blower Module (CX200 Shown) Figure 3-15 2.
Servicing and Upgrading a CX200-Series DPE2 Power Switch EMC2481 Plugging in the Power Cord and Turning on Power (CX200 Shown) Figure 3-16 3-21 Replacing a Power Supply/System Cooling Module...
Page 64
Servicing and Upgrading a CX200-Series DPE2 3-22 EMC CX200-Series DPE2 Hardware Reference...
This chapter describes the CX200 SPS and how to determine SPS status. For instructions on installing or replacing an SPS, refer to the EMC Rails and Enclosures Installation Guide for 19-Inch NEMA Cabinets. IMPORTANT: The SPS is intended to provide backup power for DAE2 and CX-Series enclosures only.
Do Not Use Module A Interface (Green) On Battery (Amber) Replace Fault Battery Power Switch Power (Amber) (Amber) Connector EMC2464 Figure 4-1 CX200 SPS See Table 4-1 for the meanings of the SPS status LEDs. EMC CX200-Series DPE2 Hardware Reference...
Page 67
The Standby Power Supply (SPS) DC SPS Status LEDs Table 4-1 Light Meaning When Lit SPS fault - Amber The SPS has an internal fault. The SPS may still be able to run on line, but write caching cannot occur. Replace the SPS as soon as possible.
Battery lifetime depends on the number of discharge cycles and depth of discharge. In a typical environment, a battery pack can last 3 to 5 years. Battery pack lifetime is shorter in locations that have frequent ac outages. EMC CX200-Series DPE2 Hardware Reference...
Specifications and Operating Limits This appendix describes the disk processor enclosure technical specifications, operating limits, and shipping and storage requirements. Major topics are CX200-Series DPE2 Technical Specifications ........A-2 Operating Limits ................A-6 SPS Technical Specifications ............A-7 Technical Specifications and Operating Limits...
IEC320-C14 appliance coupler, per power supply Ride-through time 30 ms min Current sharing 60% max, 40% min, between power supplies * A fully configured DPE2 includes 2 power supplies, 2 SPs, and 15 disk drives. EMC CX200-Series DPE2 Hardware Reference...
4.1 kg (9 lbs) per power/cooling module 2.8 kg (6.2 lbs) per blower module 12.7 kg (28 lbs) chassis and midplane Drive Type Fibre Channel interface disk drives used in CX200-Series systems are 8.75 cm (3.5-inches) wide 2.54 cm (1.0-inch) tall 12 Volt only The drive module power is 16 W maximum per drive slot.
Page 72
The maximum length when using either the 62.5 µm or 50 µm cable (noted in the table above) includes two connections or splices between the source and destination. For a detailed overview of cable types, connections, and lengths, refer to the EMC Storage System CX200-Series Configuration Planning Guide. CAUTION µm µm...
Page 73
CSA 22.2 No. 950 Safety of Information Technology Equipment including Electrical EN 60950 Business Equipment UL 1950 CE Mark European EMC Directive & Low Voltage Directive Requirements EMI Standards Standard Description FCC Part 15 Class A, Radio Frequency Device Requirements...
SP(s) and disks. Shipping and Storage Requirements Requirement Description Ambient temperature C to 65 C (-40 F to 149 Temperature gradient C/hr (45 F/hr) Relative humidity 10% to 90% noncondensing Elevation 7625 m (25,000 ft) EMC CX200-Series DPE2 Hardware Reference...
Technical Specifications and Operating Limits SPS Technical Specifications This section lists the technical specifications and operating limits for the standby power supply (SPS). SPS to SP Interface Type: Half-duplex RS-232 Baud rate: 9600, 8-bit Parity: None Power Specifications Requirement Description (All Ratings Assume Fully Configured System) ac line voltage 100 V ac to 240 V ac -10%/+10% single-phase, 47 Hz to 63 Hz;...
-40°C to 65°C (-40°F to 149°F) Gradient, maximum 25°C/hr (45°F/hr) Relative humidity 10% to 90% noncondensing Elevation 7625 m (25,000 ft) Dimensions and Battery Information Service Clearance Front 81.3 cm (32.0 in) Rear 81.3 cm (32.0 in) EMC CX200-Series DPE2 Hardware Reference...
Technical Specifications and Operating Limits Battery Tests Internal Within 60 minutes after powerup and approximately every 2 weeks thereafter, the SPS itself performs a light test on the batteries. This test lasts less than one second. It does not verify battery capacity but does check connectivity and functionality.
Page 78
EN 60950 Safety of Information Technology Equipment including Electrical UL 1950 Business Equipment. CSA 22.2 No. 950 CE Mark European EMC Directive & Low Voltage Directive Requirements. EMI Standards Standard Description FCC Part 15 Class B, Radio Frequency Device Requirements...
Page 79
Technical Specifications and Operating Limits Cable Pinout Information The SPS interface serial connector pinouts are as follows: Function Ground ENABLED_OUT AC_FAIL_OUT ANY_FAULT_OUT SPS transmit to SP SPS receive from SP SPS Technical Specifications A-11...
The 2-gigabit disk array enclosures (DAE2) supported in CX200 systems can hold 0-15 disks. DIMM (dual in-line A type of memory module used in SP memory for caching or RAID. memory module) EMC CX200-Series DPE2 Hardware Reference...
Page 82
Electronic radiation emitted by an electrical device. The levels of EMI interference) are strictly controlled for data processing equipment. The EMI standards to which the CX200-Series complies are listed in Appendix A of this manual. ESD (electrostatic The discharge of an accumulated electrical charge (static). This can...
A FRU in DAE2 enclosures, integrated into the SP module in a card) CX200-Series DPE2. An LCC connects Fibre Channel signalling to the disk modules, and provides Fibre Channel connectivity between the SP, disks, and other enclosures. It also provides bypass capability for faulted or missing units, and monitors and controls enclosure elements.
Page 84
A unit that provides temporary backup power in case of a power supply) outage. An SPS is required for storage-system write caching. If power fails, the SPS allows the SP to write the data from its cache to disk. EMC CX200-Series DPE2 Hardware Reference...
Page 85
Glossary storage processor See SP (storage processor). (SP) storage-system The procedure of temporarily storing disk-based data in SP memory caching to save time if the data is needed again soon. EMC CX200-Series DPE2 Hardware Reference...