I/O option modules

I/O option module data viewing

Option I/O modules configuration

72
Related Topics
Option modules
I/O option modules provide increased digital and analog input/output (I/O)
capabilities for your meter.
These I/O modules can be used to monitor the status of breakers, control analog
or digital transducers, or receive signals that can be interpreted to provide
WAGES data for your energy system. For applications requiring high accuracy,
such as energy pulsing to verify accuracy, the digital output on the meter base is
recommended.
NOTE: Your meter's digital and analog outputs may change state during a
firmware upgrade. Option modules are offline during an option module
firmware upgrade; they will not communicate to the meter and the outputs may
change state during the upgrade process.
Your meter's analog I/O option modules can measure and output either low
voltage or current using standard analog transducers such as 4 - 20 mA current
transducers.
View I/O option module data using ION Setup, meter webpages or through the
display.
To view option module data using ION Setup, start ION Setup and open the Setup
Assistant for your meter. Select Expansion Modules > Option I/O Modules then
select the desired I/O option module tab. If there are no I/O option modules
connected, no information other than column headers is displayed.
To view option module data using meter webpages, connect to your meter's
webpages, go to Monitoring > Inputs/Outputs and select Digital Inputs, Digital
Outputs, Analog Inputs or Analog Outputs. If there are no I/O option modules
of the specified type, no entries other than column headers are displayed.
To view option module data using the display, go to Inputs/Outputs and select
Digital Inputs, Digital Outputs, Analog Inputs or Analog Outputs.
You can configure your meter's I/O option modules using ION Setup.
The Option I/O Modules screen has tabs corresponding to the possible option
modules, which are identified based on how the option modules are connected to
the meter. Each tab indicates the module's type and status, and has an area
where the module's ports are listed for viewing and configuration. You can also
reset your meter's option modules using ION Setup.
Status examples
None
Normal
Option module added
Option module removed
Invalid S19
Invalid card
Description
No option module detected
The option module is operating normally
A new option module is detected
The option module has been removed
The option module's firmware is not supported
The option module type is not supported
Inputs / outputs