Pollution degree
Altitude
Location/mounting
Maximum operating temperature with option modules
Maximum operating temperature
70 ºC (158 ºF)
70 ºC (158 ºF)
60 ºC (140 ºF)
LEDs
Energy pulsing LEDs (visible and infrared)
Type
Wavelength
Maximum pulse rate
Status LEDs (visible)
Type
EMC (electromagnetic compatibility)
EMC standards
Immunity to electrostatic discharge
Immunity to radiated fields
Immunity to fast transients
Immunity to surges
Immunity to conducted disturbances
Immunity to power frequency magnetic
fields
Immunity to conducted disturbances, 2
- 150 kHz
Immunity to voltage dips and
interruptions
Immunity to ring waves
Conducted and radiated emissions
Surge withstand capability (SWC)
Safety
Safety construction
214
2
< 3000 m (9843 ft) above sea level
Not suitable for wet locations
For indoor use only
Must be permanently connected and fixed
948M2DO6DI
Digital (2 out, 6 in)
0 - 4
0
1, 2
Visible orange, infrared
600 – 609 nm (orange), 825 – 925 nm (infrared)
10 Hz (100 ms)
Bi-color, red/green
IEC 62052-11, IEC 61326-1, IEC 61000-6-5
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6, IEC 61000-4-16
IEC 61000-4-8
CLC/TR 50579
IEC 61000-4-11
IEC 61000-4-12
EN 55011 and EN 55032 Class B, FCC part 15 Class B, ICES-003 Class B
IEEE/ANSI C37.90.1
IEC/EN 61010-1, CAT III, 400 VLN / 690 V LL
UL 61010-1 and CSA-C22.2 No. 61010-1, CATIII, 347 V LN / 600
V LL
IEC/EN 62052-31, Protective Class II
Specifications
948M2AO4AI
Analog (2 out, 4 in)
0,1
2
2 - 4
7EN05-0390-00