Device Arrangement For Liquid Level Measurement - Samson Media 7 Mounting And Operating Instructions

Differential pressure meter with remote data transmission
Table of Contents

Advertisement

3.2.3
Device arrangement for liquid level measurement
− Fig. 3, diagram 1: measurement on cryogenic tanks
− Fig. 3, diagram 2: measurement on pressure vessels with condensing or non-condensing
pressure reserve. The additional height z is included in the measurement. As a result, this
height (z) must be as low as possible.
− Fig. 3, diagram 3: measurement on open vessels with the meter located in a low position.
The compensation height K can be as large as required depending on the conditions in
the plant.
h
Measured height
H
Measuring range
z
Additional height
K
Compensation height
h
Diagram 1
Fig. 3: Liquid level measurement · Arrangement of devices (illustration with SAMSON valve block)
EB 9510 EN
H
+
Diagram 2
z
h
H
+
Design and principle of operation
Y
+
Diagram 3
H
h
K
19