Pin Assignments of the IndraControl VCH 08.1
7.3.6

Foreseeable Misuse of the Enabling Switch

7.4
Connection of the IndraControl VCH 08.1 via the IndraCon‐
trol VAC 30.2/31.1 Connection Module
7.4.1

Overview and Important Notes

Impermissible fixing of the enabling switch in the enabling position by using
auxiliary means is considered as foreseeable misuse. Such foreseeable misuse
is to be prevented.
The following measures causing the stop of the machine in the manual mode
are recommended:
Inquiry of the enabling button when turning on the machine/plant and in‐
quiry of the enabling button when changing the operation mode from
automatic to manual (The enabling switch must not be in the enabling
position.)
The enabling button must be released within a defined period and pushed
into the enabling position again. The length of the period must be defined
according to the requirements of the activity.
WARNING
The enabling switch is only suitable as safety function if the person acti‐
vating the enabling button recognizes the dangerous situation in time so
that he or she can immediately take the necessary measures to avoid such
situations.
As additional measure reduced speed of the movement can be necessary.
The allowed speed must be determined by means of a risk assessment.
The enabling button must not be used as only component for initiating
dangerous states. For initiating dangerous states a second, intentional
start command is necessary (button on the hand-held terminal).
Only the person who operates the enabling button is allowed to work in
the dangerous area.
For further information regarding the enabling button, do observe also
chapter 4 "Technical Data" on page
The Hand-held Terminal IndraControl VCH 08.1 is connected via the Indra‐
Control VAC 30.2/31.1 connection module.
Depending on the safety components on the hand-held terminal, the following
connection modules are used:
Selecting a connection module according to safety technology applied
IndraCon‐
trol VAC 31.1
Actuating element
For hand-held ter‐
stop button, emer‐
minals with red-yel‐
gency stop button
low button
Jumpering the safe‐
Short-circuit con‐
ty circuit if the hand-
nector screwed on
held terminal is dis‐
connected
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
Non-functioning enabling device can have le‐
thal consequences!
27.
IndraCon‐
trol VAC 30.2
For hand-held ter‐
minals with black-
gray stop button
Automatic stop but‐
ton bridging
IndraControl VAM
41 /VAM 42
For hand-held ter‐
minals with black-
gray stop button
Automatic stop but‐
ton bridging