Bosch Rexroth AG
Technical Data
Enclosure rating
Dimensions
Fire resistance
Standard operating elements
OLED = Organic Light Emitting Diode)
1)
Tab. 7-2: Technical data of the keyboard, the housing and the display
7.3 Stop and EMERGENCY STOP Pushbutton
Nominal voltage
Minimum current
Maximum current
Usage category
IDEC XA series
Tab. 7-3: Technical data of the stop button and the EMERGENCY STOP pushbutton
7.4 Enabling Button
Output type
Nominal voltage
Nominal current
Switching cycles
Actuating force
Electrical isolation
Tab. 7-4: Technical data, enabling button
8/27
IP 65 (entire device)
Width: 162 mm
●
Height: 226 mm
●
Depth: 55 mm
●
UL94-V0
A 3-stage enabling button, two-circuit, externally wired
Stop button/EMERGENCY STOP pushbutton, two-circuit,
externally wired
DC 24 V
10 mA (per contact)
1000 mA (per contact)
DC-13 (acc. to IEC 60947-5-1)
B
: 100 000
10d
Solid-state output
DC 24 V (voltage tolerance DC 19.2 V to DC 30 V acc. to EN
61131-2)
Max. 500 mA
Switch position 2: 10
●
Switch position 3: 10
●
From switch position 1 to 2: 3 N typically
●
From switch position 2 to 3: 17 N typically
●
AC 500 V
●
6
5
DOK-SUPPL*-VCH*05*****-IT02-EN-P
VCH 05.1