4-2
Technical Data
4.4
Enabling Device
Design
Nominal voltage
Nominal current*
Prescribed external protection
Operating cycles
Control category
4.5
Connection Module IndraControl VAC 30.1
Connections
Prescribed external protection
Material
Degree of protection
3-stage enabling switch*, 2-channel, electrically isolated
24-VDC-/30-VAC safety extra-low voltage
2 A= / 2,3 A~ current carrying capacity of the output contacts is limited by
the connected cable
2-A-fusible cut-out, time-lag
>200,000 for the enabling range, >100,000 for the panic position
Usable in safety-related controls up to Kat.4, DIN EN 954-1 (if required
with additional monitoring modules)
Fig. 4-4:
Technical data of the enabling device
* Protect lines against short-circuits and/or cross-circuits caused by the
installation!
•
1 x Ethernet connection (RJ 45, 10/100 Base-T)
•
STOP pushbutton
•
Enabling device
•
Voltage supply 24 V (see IndraControl VEH 30.1)
2-A-fusible cut-out, time-lag
Front panel: Aluminum, metal cover: V2A
Front panel IP 65, rear side IP 30, type 1 according to NEMA (UL)
Fig. 4-5:
Technical data of the IndraControl VAC 30.1
IndraControl VEH 30.1
DOK-SUPPL*-VEH*30.1***-PR02-EN-P