System Cables
Before installing the system cables, you need to take the following points into
consideration.
1. All cables need to be well clamped and protected from physical damage
and exposure to heat and humidity.
2. Cable with an acute bend is not allowed.
3. Where a cable passes through an exposed bulkhead or deck head,
a watertight gland or swan neck tube should be used.
Due to the voltage losses across the length of the RF coax on L-Band, Intellian
recommends the following 50 ohm coax cable types for standard system
installations. For cables that run longer than 200 meters, please consult Intellian
Technologies.
Recommended
Coaxial Cable
RF Cables
Type
LMR300
LMR400
LMR500
LMR600
LMR900
LMR1200
Recommended
Cables
Type
Number of wires
Power Requirement
Intellian v100GX has been designed to work on a vessel's power supply rated at
100-240V AC.
Attenuation in
Attenuation in
dB/100M
dB/M
30.3
0.303
19.6
0.196
15.9
0.159
12.8
0.128
8.6
0.086
6.5
0.065
Multi-conductor, Shielded
2 conductors for NMEA/NMEA2000
INSTALLING THE ANTENNA
Recommended
Cable Length
35M
60M
80M
100M
150M
200M
19
Need help?