Intellian v100GX Installation And Operation Manual page 132

Ku-to-ka convertible
Hide thumbs Also See for v100GX:
Table of Contents

Advertisement

v100GX – Marine Satellite Communication System
132
SNMP Setting
2
3
4
5
6
7
8
1
No.
Item
SNMP Setting
1
V1/2 Attribution
2
V3 Attribution
3
V3 Username / Password
4
TRAP IP / Port
5
System Reset Notification
6
Port Connect Notification
7
Port Disconnect
8
Notification
Description
Configure SNMP settings.
Configure the SNMP v1/v2 attributes (Read-Only,
Read- Write, Disable). The community name of SNMP
v1 / v2 is "public".
Configure the SNMP v3 attributes
(Read-Only, Read- Write).
Set a v3 username & password of the SNMP agent.
Set the trap IP address and socket number of the
SNMP trap server. Trap feature will be disabled if the
trap IP is set to 0.0.0.0.
Enable or disable the system reset SNMP trap
notification.
Enable or disable the port connect SNMP trap
notification.
Enable or disable the port disconnect SNMP trap
notification.