Zone Label <>
O
Zone Label <>
B
Bypassed zones:
Must be configured before arming the system.
l
Can be configured using a keypad.
l
Allow for access to protected areas when the system is armed.
l
Allow you to arm the system if a zone is temporarily out of service.
l
Reduce the level of security.
l
Will not sound an alarm.
l
Are automatically cancelled each time the system is disarmed.
l
Can be programmed together within bypass groups. For more information see "Bypass Groups".
l

4.9.1 Additional Bypass Features

Recall Last
Recalls all zones that were bypassed the last time the bypass zone feature was
Bypass
used.
Bypass All Open
Allows the user to quickly bypass all open zones with a single command.
Zones
Clear Bypass
Instantly clears all bypass conditions from the zones assigned to the partition.
Programming a
Use when you consistently bypass the same zones. This feature allows you to store
Bypass Group
in memory one group of bypassed zones per partition.
Activating a
Loads a stored bypass group from memory.
Bypass Group
NOTE: Ensure that no zones are unintentionally bypassed when arming the system.
NOTE: 24-hour zones can only be unbypassed manually.
NOTE: For security reasons, your installer has programmed the system to prevent you from bypassing
certain zones (e.g., smoke detectors). For more information on fire zones see "Fire and CO Zone Types".
To Bypass Individual Zones
1.
Press [*] [1]. If required enter your access code or present your prox-
imity tag.
2.
Directly bypass zones by entering the 3-digit zone #.
OR
Scroll to the desired zone using the [<][>] keys and press [*].
3.
To toggle and unbypass a zone re-enter the 3-digit zone # or press
[*] again. To bypass more zones repeat steps 3 and 4.
4.
To exit bypassing mode press [*].
5.
If the system is ready to arm the Ready indicator will be lit. When arm-
ing the system, a bypass warning briefly displays.
To Bypass All Open Zones
1.
Press [*][1]. If required enter your access code or present your prox-
imity tag.
O
Zone is currently open. You may be unable to arm the
system.
B
Zone is bypassed.
-
-
13
LCD Display
Zone Bypass <>
(*) To Bypass
Zone 1 <>
0
Zone 1 <>
B
LCD Display
Zone Bypass <>
(*) To Bypass