Use the EX6010 rackmount extension unit to add additional components and configuration options. The unit expands the DCS
chain into 4 separate outputs, each with a power supply equivalent of a CCU.
Note: Cable redundancy in can be achieved using the EX6010 by connecting the DCS-LAN OUT port of the last conference unit to an MXC Redundancy Inter-
face Box (MXC-ACC-RIB), and looping back to a DCS-LAN port on the same EX6010.

Troubleshooting

Attention: Always use shielded Cat 5e (or higher) network cables for reliable system operation. Ensure the right cables are
used and installed correctly before referencing the troubleshooting table.
The light rings on the microphone are
constantly flashing after the system is
powered on.
Inline Power Supply (1x)
Rackmount Power Supply (x4)
Check that cables are shielded Cat 5e (or higher)
Ensure that all the connectors on all the cables are firmly inserted in the sock-
ets on the units
Check that the feeding cables from the conference units are properly inserted
into the 'DCS-LAN' socket on the DIS-CCU.