4.
Press the <SELECT> button.
The <ALL> light will light up to indicate the following:
- the system operation has been checked to ensure its correct functioning,
- the sequence of all columns is stored in the system memory
- the master column in the system has been connected to the mains,
- the height of every column has been saved in the memory,
- the column lifts can now be operated.
5.
All system functions are now available (the default is <ALL> all columns):
- button 3 all columns will rise,
- button 4 all columns will lower in the safeguard,
- buttons 6 and 4 all columns will lower.

5.3.2 Pair operation

Note
n
Setting to the pair operation (only possible when you have an even number of
column lifts):
1.
Select the master columns at one axle to set this function (for example, the front
wheel axle).
2.
Press the <SELECT> button until the <PAIR> light starts to flash.
Next, select the other column of "the pair".
3.
Go to the other column of "the pair" and press <SELECT> until the <PAIR> light is
continuously lit. Now "the pair" has been selected.
4.
Press button 3 to raise "the pair" columns.
Press button 4 to lower "the pair" columns.
Note
n
An acoustic signal will be emitted when "PAIR" UP and DOWN is operational
because this is an exceptional situation.
Note
n
When a pair operation is set up, the other axle pairs are also automatically selected
as a pair in the operating system. This will only work correctly if all column lifts have
been configured in a closed circuit according to
page
28.
Operating instructions (Version F)
Figure 4.2 "Linking columns" on
38