Emergency Shut-Down Button; Starting - stertil-KONI ST 1082-FS Installation, Operation And Maintanance Instructions

Mobile column lift
Table of Contents

Advertisement

5
These two control boxes are identical externally except that the control box of a
slave column has an emergency shut-down button instead of a main switch (that is
also used as an emergency stop button) and it does not have mains supply. For the
functions of the switches refer to
To the following
column
1. Emergency button
2. Main switch
3. UP
4. DOWN
Figure 5.1 Control boxes
Note
n
Operate the panel only with your fingertips. Pressing the buttons using sharp objects
(such as screwdrivers) can damage the equipment and cause errors.

5.2.1 Emergency shut-down button

If the emergency shut-down switch (main box) is set to 0 or the emergency shut-
down switch (auxiliary box) is pressed, all movements (lifting and lowering) will be
immediately stopped.

5.2.2 Starting

The mains switch (2) controls the power supply to the column lifts. This switch has
two positions:
0 (OFF)
This will interrupt the power supply to the column lift(s).
1 (ON)
This will activate the power supply to the column lift(s).
Operating instructions (Version F)
Operation
Master column
5. <SELECT> button
6. Unlocking
7. Slow lowering selection
Figure 5.1 "Control
Mains supply
button
35
boxes".
Slave column
To the following
column
8. <FAULT> indicator
9. <ALL> indicator
10. <SINGLE> indicator
11. <PAIR> indicator
ST 1082 & ST 1100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St 1100-fsSt 1082-rsSt 1100-rs

Table of Contents