Service And Repair Section; Playfield Access; Coin Sensor Switch Replacement - Bay-Tek Deep Freeze Owner's Manual

Table of Contents

Advertisement

SERVICE AND REPAIR SECTION

CAUTION:
Hazard.
Do not perform maintenance
or repair of this equipment
with power ON. Unplug the
unit from the wall outlet or shut off power at
the power strip inside the cabinet.

Playfield Access

1. Turn power OFF at the power strip located
inside the back door of the game or unplug the
game from the wall outlet.
2. Unlock and lift off the control service panel.
LIFT GLASS AT FRONT AND REMOVE
UNLOCK AND LIFT OFF PANEL
Figure 7 Glass Removal
3. Lift the tempered glass on the front edge
and pull toward the front. Remove and set
aside.
4. Perform maintenance or cleaning.
CAUTION: Use of flammable
substances can cause severe
burns or personal injury.
Always
solvents for cleaning parts and
surfaces of this game. Do not use flammable
substances such as gasoline, kerosene or
thinners.
Deep Freeze
Electrical
Shock
use
non-flammable
5. After performing maintenance or cleaning,
replace the glass and secure by locking the
control service panel in place.
6. Test the game to insure proper operation.
Coin Sensor Switch
Replacement.
1. With power to the game OFF, gain access
to the playfield as described above, for easier
access to the sensor.
2. Disconnect the two wires at the switch
terminals.
3. Remove the two Phillips head machine
screws holding the switch in place and remove
the switch.
COIN TRIP WIRE NORMAL POSITION
Figure 8 Coin Sensor Limit Switch
4. Install the new switch being careful not to
bend the coin trip wire. Secure with two
machine screws.
5. Reconnect wires as shown in Figure 8. Be
sure that they are tight on the terminals. If not,
pinch tight with a pliers.
6. Reinstall top glass and control service panel
and check operation of the game.
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents