Emerson Rosemount 3051S Quick Start Manual page 44

High static differential pressure transmitter
Hide thumbs Also See for Rosemount 3051S:
Table of Contents

Advertisement

Quick Start Guide
3. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic build-up
on painted surfaces, and only clean the painted surfaces with a damp
cloth. If paint is ordered through a special option code, contact the
manufacturer for more information.
4. Appropriate cable, glands and plugs need to be suitable for a
temperature of 5 °C greater than maximum specified temperature for
location where installed.
5. Cable entries must be used which maintain the ingress protection of
the enclosure to at least IP66.
6. Unused cable entries must be filled with suitable blanking plugs which
maintain the ingress protection of the enclosure to at least IP66.
7. Cable entries and blanking plugs must be suitable for the ambient
temperature range of the apparatus and capable of withstanding a 7 J
impact test.
8. The Rosemount 3051S SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
I7 IECEx Intrinsic Safety
Certificate
Standards
Markings
Model
SuperModule
3051S...A; 3051SF...A;
3051SAL...C; 3051SHP...
D...A
3051S...F; 3051SF...F;
3051SHP...D...F
3051S...F...IA; 3051SF ...F...
IA; 3051SHP...D...F...IA
3051S ...A...M7, M8, or M9;
3051SF ...A...M7, M8, or
M9;
3051SAL...C... M7, M8, or
M9;
3051SHP...D... M7, M8, or
M9
3051SAL; 3051SAM
44
IECEx BAS 04.0017X
IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC T4 Ga, T4(–60 °C ≤ T
U
i
30 V
30 V
30 V
17.5 V
30 V
30 V
≤ +70 °C)
a
I
P
i
i
300 mA
1.0 W
300 mA
1.0 W
300 mA
1.3 W
380 mA
5.32 W
300 mA
1.0 W
300 mA
1.0 W
February 2019
C
L
i
i
30 nF
0
12 nF
0
0
0
0
0
12 nF
60 μH
12 nF
33 μH
Rosemount 3051SHP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 3051shp

Table of Contents