User Guide
DVS-21
Message
Specification of the precise duration of the recording(Unit = value x 50, 100, 150 or
duration
200ms)
Interval time
Pause between automatic repeats (Unit = value x 50ms)
Flag (NAND)
[IN] The program can be turned off by this flag or switching on can be prevented.
Flag (OR)
[IN] The program can be switched on by this flag.
9.4 IC Intercom
Program to establish local IC connections
For one connection between two call stations, two programs are used. Each program is programmed on
a key of the call stations involved.
The program is compatible with the
set up in this way.
In each case the association arises from the Station number of Destination call station. Specification of
the Destination call station is required in both programs. All further specifications are optional.
Priority
Handling of priorities
Audio compression method by which the codec handles the actual connection.
Codec
The options are: µLaw (default), ADPCM (7kHz) and aLaw
The connection is established and remains one-sided until the key is pressed again.
Latching key
The remote station can reverse the direction and reply. The priorities can be the
same.
Own/Analog
Selects the type of call station (ProCom- or Analog- call stations).
Input/call station (Setting Own)
Address and port of the module to which the call station is connected and the line
Address, Port, Line
(key) that is used. (4NSA)
Input/call station (Setting Analog)
Address and port of the module to which the AF line of the call station is connected.
Address AF, Port
(4NPA)
Address 24LI, Port,
Address, port and line of the module to which the control line of the call station is
Line
connected. (24LI)
Call storage
Time for the key is illuminated (flashing) after missed calls
Destination call station
The address of the destination is specified directly and not determined via the
To enter address
Station number.
Station number
Unique number of the Destination call station
02/2018 • V.1.0 • L. Wolle
© 2017 ProCom
IC Intercom gate
program! Unilaterally-controlled connections can be
(see Section
®
Professional Communication & Service GmbH • Technical changes reserved.
9.1)
(see Section
9.1)
79/131
Need help?
Do you have a question about the DVS-21 and is the answer not in the manual?
Questions and answers