3.1 Scope of delivery
The following items are included in the scope of
delivery (possible variations due to country-spe-
cific requirements and/or import regulations):
ProVecta 3D Prime                  A7750
– Fiber optic cable 10m / 33ft
– Exposure switch and holder
– Adapter for bite block
– Bite block
– Chin holder for edentulous jaws
– Chin holder for maxillary joint image
– Chin holder for sinus image
– Head supports with cushion
– Wall bracket top (16 in)
– Hygienic protective covers for bite block (100
pieces)
– Small parts set (eg screws, nuts)
– Operating instructions
– Installation instructions
– PCI Express frame grabber card
– USB dongle
– USB stick containing device-specific calibra-
tion data
If the mains cable of this unit is damaged
it must only be replaced by an original
mains cable from the manufacturer

3.2 Accessories

The following items are required for operation of
the device, depending on the application:
Hygienic protective cover bite block
(100 pieces)                       A7395
Positioning aids
Adapter for bite block                A7375
Bite block (3 pieces)                 A7395
Chin holder for edentulous jaws        A7390
Head supports Plus with cushion       A7752
Cushion for head supports Plus        A7753
Chin holder for mandibular joint image    A7391
Chin holder for sinus image            A7392
2210200497L41 1812V002
3.3 Special accessories
The following optional items can be used with
the device:
Bottom wall bracket set, 16 inch,
short (wall/wall installation)            A7754
Fiber optic cable 5m                 A7757
Fiber optic cable 20m                A7758
Acceptance and consistency check
Test body set for Pano               A7556
Consistency check test body 3D set     A7759
Acceptance test body 3D             A7760
Ball phantom                      A7330

3.4 Consumables

The following materials are consumed during
operation of the device and must be re-ordered:
Hygienic protective cover bite block
(100 pieces)                       A7395
Cleaning and disinfection
Monarch surface disinfection wipes
(hundred pcs - 7" x 9")               H6171
Monarch enzymatic cleaner (845 oz
bottle)                            H6201
Information on replacement part is avail-
able at the portal for authorized specialist
dealers: