Mitsubishi Electric MELSEC iQ-R Series User Manual page 73

Ethernet/ip network interface module, application
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• When "Identity" is selected for "Object"
Item
Identification
Vendor ID
Device Type
Product Code
Revision
Serial Number
Product Name
Status
Owned
Configured
Extended Device Status
Major Unrecoverable Fault
Major Recoverable Fault
Minor Unrecoverable Fault
Minor Recoverable Fault
• When "Connection Manager" is selected for "Object"
Item
Open Counters
Open Requests
Format Rejects
Resource Rejects
Other Rejects
Close Counters
Close Requests
Format Rejects
Other Rejects
Others Counters
Connection Timeouts
Number of Connection
Description
Displays the vendor code of the RJ71EIP91. (Fixed to 161.)
Displays the module type of the RJ71EIP91. (Fixed to 12.)
Displays the product code of the RJ71EIP91. (Fixed to 8.)
Displays the version of the RJ71EIP91.
Displays the serial number of the RJ71EIP91.
Displays the product name of the RJ71EIP91. (Fixed to the RJ71EIP91.)
Displays the connection status between the RJ71EIP91 and the EtherNet/IP device (adapter and
scanner).
• TRUE: The adapter and scanner are connected.
• FALSE: The adapter and scanner are not connected.
Displays whether the settings of the RJ71EIP91 were configured with EtherNet/IP Configuration Tool.
(Excluding TCP/IP-related settings)
• TRUE: Settings have been configured.
• FALSE: Settings have not been configured. (Operations are being performed with the default settings.)
Displays the operation mode of the RJ71EIP91.
• At least one faulted I/O connection: Error occurring on one or more connection
• No I/O connections established: No connections established
• Major Fault: Major Recoverable Fault or Major Unrecoverable Fault occurring
• At least one I/O connection in run mode: One or more connection performing normal communication in
RUN mode
• At least one I/O connection established, all in idle mode: One or more connection all performing
communication in IDLE mode
Displays the main major error status of the RJ71EIP91. (Unrecoverable error)
• TRUE: Major error occurring
• FALSE: Major error not occurring
Displays the main moderate error and minor error status of the RJ71EIP91. (Recoverable error)
• TRUE: Moderate error or minor error occurring
• FALSE: Moderate error or minor error not occurring
Displays the major error status of the RJ71EIP91. (Unrecoverable error)
• FALSE: Major error not occurring (fixed)
Displays the moderate error and minor error status of the RJ71EIP91. (Recoverable error)
• TRUE: Moderate error or minor error occurring
• FALSE: Moderate error or minor error not occurring
Description
Displays the number of open requests received from the connected EtherNet/IP device.
Among the open requests received by the RJ71EIP91, displays the number of rejected open requests
due to message format errors.
Among the open requests received by the RJ71EIP91, displays the number of rejected open requests
due to insufficient resources.
Among the open requests received by the RJ71EIP91, displays the number of rejected open requests
due to reasons other than message format errors and insufficient resources.
Displays the number of close requests received from the connected EtherNet/IP device.
Among the close requests received by the RJ71EIP91, displays the number of rejected close requests
due to message format errors.
Among the close requests received by the RJ71EIP91, displays the number of rejected close requests
due to reasons other than message format errors.
Displays the number of timeouts that occurred in connections with EtherNet/IP devices.
Not supported in the RJ71EIP91.
3 EtherNet/IP Configuration Tool
3.1 Window Structure
3
71