Buffer memory
The following tables list the differences between the QJ71EIP71 and the RJ71EIP91 buffer memory areas.
Address (decimal)
Address
(hexadecimal)
0 to 4095
0H to FFFH
4096 to 8191
1000H to 1FFFH
8192 to 12287
2000H to 2FFFH
12288 to 16383
3000H to 3FFFH
16385
4001H
16386 to 16387
4002H to 4003H
16629
40F5H
16630
40F6H
16631 to 16632
40F7H to 40F8H
16633
40F9H
16634
40FAH
16635
40FBH
16636
40FCH
16640 to 17151
4100H to 42FFH
17152 to 21119
4300H to 527FH
25728
6480H
25733 to 25735
6485H to 6487H
25783
64B7H
25856 to 26367
6500H to 66FFH
26368 to 26879
6700H to 68FFH
27008 to 27055
6980H to 69AFH
27072 to 27119
69C0H to 69EFH
27136 to 27183
6A00H to 6A2FH
27184 to 27231
6A30H to 6A5FH
27264
6A80H
27265 to 27267
6A81H to 6A83H
27268
6A84H
27392 to 27647
6B00H to 6BFFH
27648 to 27903
6C00H to 6CFFH
27904 to 27907
6D00H to 6D03H
27908 to 27911
6D04H to 6D07H
28160 to 28170
6E00H to 6E0AH
28288
6E80H
28290 to 28341
6E82H to 6EB5H
32768 to 33279
8000H to 81FFH
65536 to 98303
10000H to 17FFFH
196608 to 229375
30000H to 37FFFH
393216 to 393249
60000H to 60021H
393280 to 442431
60040H to 6C03FH
QJ71EIP71
Class1 Input Area
Class3/UCMM Input Area
Class1 Output Area
Class3/UCMM Output Area
DHCP setting
IP Address
System area
System area
System area
Battery error detection setting
Tag com. continue setting
Tag com. continue setting status
Class1 Tag Counts
Class1 Tag Parameter
Intelligent function module switch status
Ethernet address (MAC address)
Battery status
Class1 send/receive data start address
Class3/UCMM send/receive data start address
Application Trigger (Class1)
Application Trigger (Class3/UCMM)
Communication status (Class1)
Communication status (Class3/UCMM)
Own station error status
TCP/UDP/IP parameter error information
Self-diagnostics execution result
Class1 Diagnostics Information
Class3/UCMM Diagnostics Information
PING test request area
PING test result area
System area
Appendix 6 Differences Between QJ71EIP71 and RJ71EIP91
RJ71EIP91
System area
Block assurance state per connection
Block assurance state per connection
Application Trigger operation specification
(Class1)
System area
EtherNet/IP data link continuation specification
request
EtherNet/IP data link continuation specification
state
System area
Class1 I/O data size
System area
System area
MAC Address
System area
Class1 I/O data start offset address
System area
Application Trigger (Class1)
System area
Class1 communication status
System area
Class1 Connection Behavior Error status
System area
PING test request area
PING test result area
Node information area
Connection information read request area
Connection information read response area
Class1 Block assurance specification per
connection
Class1 Input Area
Class1 Output Area
UCMM data link execution command
UCMM data link request command (No.1 to
No.32)
UCMM data link receive command (No.1 to
No.32)
APPX