EtherNet/IP data link continuation specification
■EtherNet/IP data link continuation specification request (Un\G16634)
This address is used to set whether to continue EtherNet/IP communications when 'EtherNet/IP communication start request'
(Y10) is turned on and off.
Set this address to continue EtherNet/IP communications in situations such as when the CPU module changes from the RUN
state to the STOP state and when a stop error occurs on the CPU module.
The setting is reflected when 'EtherNet/IP communication start request' (Y10) is turned off and on.
• 0: Stops EtherNet/IP communications.
• 16: Continues EtherNet/IP communications.
■EtherNet/IP data link continuation specification state (Un\G16635)
This address is used to store the setting status of 'EtherNet/IP data link continuation specification request' (Un\G16634).
The setting is reflected when 'EtherNet/IP communication start request' (Y10) is turned off and on.
• 0: The 'EtherNet/IP data link continuation specification request' (Un\G16634) setting has not been reflected.
• 1: Operation is in progress with the setting for continuing EtherNet/IP communications.
• 2: Operation is in progress with the setting for stopping EtherNet/IP communications.
Class1 I/O data size
■Class1 Input data length (Un\G16640 to Un\G16895)
This address is used to store the size of the data received by the RJ71EIP91 from the EtherNet/IP device during Class1
communications. (Unit: words)
Address
Un\G16640
Un\G16641
Un\G16895
■Class1 Output data length (Un\G16896 to Un\G17151)
This address is used to store the size of the data to send to the EtherNet/IP device from the RJ71EIP91 during Class1
communications. (Unit: words)
Address
Un\G16896
Un\G16897
Un\G17151
Setting status
■MAC Address (Un\G25733 to Un\G25735)
Stores the MAC address of the RJ71EIP91.
The MAC address is stored starting with the lower-order word.
Ex.
For MAC address 08-00-70-00-1A-34
Address
Un\G25733
Un\G25734
Un\G25735
APPX
146
Appendix 3 Buffer Memory
Description
Stores the input data size of connection number 1.
Stores the input data size of connection number 2.
Stores the input data size of connection number 256.
Description
Stores the output data size of connection number 1.
Stores the output data size of connection number 2.
Stores the output data size of connection number 256.
Stored value
1A34H
7000H
0800H
Description
First lower-order word of MAC address
Second lower-order word of MAC address
Third lower-order word of MAC address