Error Codes
A1
A2
A3
AA
AB
BNF Stop Sensor 1
53
81
82
85
86
EA
A1
A2
A3
A4
A5
A8
BNF Stop Sensor 2
AA
54
AB
81
82
85
86
EA
A1
A2
A3
A4
A5
BAU Front Positioning
A8
57
AA
AB
81
82
85
86
A1
A2
A3
A4
A5
Holding Transport
A8
59
Positioning Sensor 1
AA
AB
81
82
85
86
A2
81
BNF Remaining Sensor 2
5A
82
F1
P/N 960-000186R_Rev. A {EDP #253995}
RDM-100™ Series Retail Deposit Module
Table 10 General Fault Conditions (Continued)
Part
Sensor ON before Initial Movement starts
Sensor ON when Initial Movement starts
Sensor ON when Initial Movement stops
Sensor ON when counting starts
Sensor ON when counting stops
(S03)
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
Sensor Offset Error - DA Value Low
Sensor Offset Error -DA Value High
Banknote Reset Requirement
Sensor ON before Initial Movement starts
Sensor ON when Initial Movement starts
Sensor ON when Initial Movement stops
No Sensor ON within the time range specified
Sensor ON (Never OFF)
No Tracking Data
Sensor ON when counting starts
(S04)
Sensor ON when counting stops
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
Sensor Offset Error - DA Value Low
Sensor Offset Error -DA Value High
Banknote Reset Requirement
Sensor ON before Initial Movement starts
Sensor ON when Initial Movement starts
Sensor ON when Initial Movement stops
No Sensor ON within the time range specified
Sensor ON (Never OFF)
No Tracking Data
Sensor 1
Sensor ON when counting starts
(S07)
Sensor ON when counting stops
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
Sensor Offset Error - DA Value Low
Sensor Offset Error -DA Value High
Sensor ON before Initial Movement starts
Sensor ON when Initial Movement starts
Sensor ON when Initial Movement stops
No Sensor ON within the time range specified
Sensor ON (Never OFF)
No Tracking Data
Sensor ON when counting starts
(S09)
Sensor ON when counting stops
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
Sensor Offset Error - DA Value Low
Sensor Offset Error -DA Value High
Sensor ON when Initial Movement starts
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
(S10)
No Banknote at Insertion Slot before counting
Description
© 2016, JAPAN CASH MACHINE CO., LTD.
2 9
Remarks
*
Warning Code
*
Warning Code
*
Warning Code

Hide quick links: