8 TROUBLESHOOTING

This section provides troubleshooting instructions
for the RDM-100 Banknote Validator Units, includ-
ing the following information:

• Introduction

• Troubleshooting Overview

• Fault Table Listings

Introduction
Most Banknote Validator failures result from minor
causes. Before replacing any parts, be sure that all
assembly and circuit board connectors are properly
fitted with their harnesses properly connected.
Poor performance by the RDM-100 Banknote 
Validator is often caused when dust or foreign
objects adhere to the sensors or rollers. Clean the
Banknote validation section first, then carefully
observe the operating state of the Validator when
re-initializing power. This observation is important
in locating any causes of failure and the possible
fault location.
Error Codes
93
94
95
11
97
98
99
12
91
13
90
62
64
14
Flash Memory
65
66
**
71
30
72
A3
B4
A2
81
BNF Start Sensor 1R
50
82
F1
A2
81
BNF Start Sensor 1R
51
82
F1
A2
81
BNF Remaining Sensor 1
52
82
F1
P/N 960-000186R_Rev. A {EDP #253995}
RDM-100™ Series Retail Deposit Module
Table 10 General Fault Conditions
Part
Sensor Calibration Error
EEPROM
Production Number Error
Software Switch Data Error
Read Error
Write Error
Data Error
RTC Error
RTC
Backup Error
SRAM
Flash Memory Erase Error
Flash Memory Program Error
Erase Verify Error
Address Error
BAU Relative Error
Communication Error
BAU
Accept Notice Full
Remaining Note Detection After Initializing
Latch Set Error During Initializing
Sensor ON During Initializing
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
(S01R)
No Banknote Before Counting Starts
Sensor ON During Initializing
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
(S01L)
No Banknote before counting starts
Sensor ON During Initializing
Sensor Calibration Error - DA Value Low
Sensor Calibration Error - DA Value High
(S02)
No Banknote before counting starts
Perform all repairs by referring to Calibration and
Testing in Section 6 of the RDM-100 Operation and
Maintenance Manual, and the Disassembly/Reas-
sembly instructions in Section 4 of the RDM-100
Operation and Maintenance Manual.
Troubleshooting Overview
This product allows the operator to perform fault
diagnosis by checking various Fault Table Listings
against the symptoms. Survey the cause(s) of any
failure occurrences during the process.
After determining the cause of the failure, execute
the Performance Test, and then repair the unit
replacing any appropriate parts deemed necessary.
Fault Table Listings
Table 10 lists the various possible RDM-100 Unit
fault conditions that can occur and the necessary
actions required to correct them.
Description
© 2016, JAPAN CASH MACHINE CO., LTD.