Features and Concepts
the Auxiliary Output, without checking any Time Zones. The
mode LED will be orange.
The Mode LED is orange

Secure Mode

• The Mode LED is red
In Secure Mode, the OUT Reader (the reader that is installed
inside the premises) is the only functioning reader. The IN
Reader (the reader that is installed outside the premises) will
only accept the Duress Code. The REX button functions
normally.
The controller's programming keypad is also functioning,
allowing the entry of Employee Codes, Duress Code, Lock
Strike Code, and Auxiliary Code.
While in Secure Mode, the controller cannot be programmed
from the controller's programming keypad. The controller can
only be programmed using the PC interface.

3.3 Changing the Modes of Operation

Changing from Normal Mode to Secure Mode

1. The controller is in Normal Mode
• The Mode LED is green
2. Present your Normal / Secure Code to one of the external
readers, or enter your Normal / Secure PIN Code at the
controllers programming keypad.
If your Normal / Secure PIN Code is less than 6-digits long,
do not forget to press the "#" key to confirm your entry
after entering your Normal / Secure PIN Code.
• Mode LED will turn red
You are now in Secure Mode

Changing from Secure Mode to Normal Mode

1. The controller is in Secure Mode
• Mode LED is red
Page 17
AC-115 Hardware Installation and User's Guide
Mode
Door
Red
Mode
Door
Green
Mode
Door
Red
Mode
Door
Red

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC-115 and is the answer not in the manual?

Table of Contents