• N2 - determines if the internal siren is activated when a
Forced Door Event occurs.
Enter "1" to enable this feature
Enter "0" to disable this feature
4. If the 2-digit Forced Door Event settings are entered
correctly, the Forced Door Event will be updated and the
controller will return to Programming Mode.
The Mode LED will turn orange
If the 2-digit Forced Door Event settings are entered
incorrectly, the Forced Door Event settings will NOT be
updated. You will hear a long beep and the controller will
exit Programming Mode and return to Normal Mode.
The Mode LED will turn green

4.25 Setting up the Tamper Event Actions

1. Enter Programming Mode
• Mode LED will turn orange
2. Press "43" to enter Menu 43
• The Mode LED will turn red
3. Enter the 2-digit Tamper Event settings.
• N1 - determines if the auxiliary relay is activated when a
Tamper Event occurs.
Enter "1" to enable this feature
Enter "0" to disable this feature
• N2 - determines if the internal siren is activated when a
Tamper Event occurs.
Enter "1" to enable this feature
Enter "0" to disable this feature
4. If the 2-digit Tamper Ajar Event settings are entered
correctly, the Tamper Event settings will be updated and
the controller will return to Programming Mode.
The Mode LED will turn orange
If the 2-digit Tamper Event settings are entered incorrectly,
the Tamper Event settings will NOT be updated. You will
AC-115 Hardware Installation and User's Guide
Programming Instructions
Mode
Mode
Mode
Mode
Mode
Door
Orange
Door
Green
Door
Orange
4
3
Door
Red
N1 N2
Door
Orange