Description
2.3 General layout SINAMICS G110M system
Option
Internal braking resistor
(FSB)
Glanded connector kit
HanQ connector kit
Repair Switch
Wall Mount Kit (WMK)
2.3
General layout SINAMICS G110M system
Introduction
The locations and description of the various interface connections of the CU240M Terminal
housing (including the Control Module (CM)) and the PM240M Power Module (PM) are
detailed in the figure and table below.
The layout and interfaces of the AS-i variant is shown in a separate figure and table below.
The connections on the terminal housing are delivered with either HAN Q (pluggable) or
Glanded connectors depending on the variant that has been ordered.
18
Description
Continuous braking power 20 W, peak power 200
W (load period t
=12s over a period t=240s) re-
a
sistance 175 Ω
Comprises the following connectors:
M20 screw gland - used for 24 V power sup-
•
ply daisy chain
M25 plastic gland - used for the 3-phase
•
mains daisy chain
M12 plastic gland - used for the EM-brake
•
cable entry.
Comprises the following connectors:
Connector cap 7/8th internal thread - used for
•
the 24 V power blanking cap
HanQ blanking cap - used for the mains input
•
blankingcap
M12 plastic gland - used for the EM-brake
•
cable entry.
The Repair Switch allows the motor/converter to
be isolated from the mains. This means that all
power to the motor is terminated and the con-
verter cannot start or stop the motor.
The WMK allows the converter to be mounted on
a wall or flat surface separate from the location of
the motor.
Getting Started, 01/2016, FW V4.7.6, A5E36100338B AD
Article number
6SL3501-0BE22-0AA0
6SL3566-2VA00-0GA0
6SL3566-2LA00-0GA0
6SL3555-0PR01-0AA0
6SL3566-1GA00-0GA0
Distributed converter for SIMOGEAR geared motors