4. Remove the internal braking resistor
5. Remove the terminal housing terminal connectors
Distributed converter for SIMOGEAR geared motors
Getting Started, 01/2016, FW V4.7.6, A5E36100338B AD
1. Remove the internal resistor holding clamp.
2. Disconnect the brake resistor wires from the motor
terminals (R2 and R1).
3. Slide the internal braking resistor out from the terminal
housing.
Note:
• The internal braking resistor is an optional extra and should
be fitted to the terminal housing.
• The internal braking resistor must not be fitted on the same
side as the CPI.
1. Remove the mains terminals connector
2. Remove the motor terminals connector
Notes:
• The terminal connectors are removed to allow easy access
to the earthing posts located underneath the individual
terminals.
• There are no screws holding down the connectors - they
are secured and held in place when the Control Module is
fitted.
Installation