General Visualization Parameters - Siemens SIMOVERT MASTERDRIVES 6SE7087-6CX86-2BA1 Manual

Active front end (afe) afe rectifier / regenerative feedback unit ac-dc modular design for construction types e to j
Table of Contents

Advertisement

Parameter List
12.1

General visualization parameters

PNU
Parameter Name in OP1
*:conf-P
Description
r000
Operation Display
Displays the operating status, fault and alarm messages
See Section "Operator control" for a description
r001
Operating status
Visualization parameter indicating the current operating state
1Hex
of the AFE
Description
0 = AFE MLFB input
1 = AFE initialization
2 = Hardware initialization
3 = Closed-loop control initialization
4 = Hardware settings
5 = Closed-loop control settings
7 = Fault
8 = Starting lockout
9 = Ready for ON
10 = DC-link precharging
11 = Ready to run
14 = Run
18 = Forming
21 = Downloading parameter settings ....
Analog output: 100 % with code number (PWE) = 16384
Type = O2;
r004
Output Amps
AFE output current (fundamental r.m.s.)
Note:
The displayed value corresponds to the current at
4Hex
the inverter (CT). The line current at the AFE input
deviates from this value by the current component
which flows through the filter capacitor.
Analog output: 100 % with code number (PWE) = 4 * P072
Type=O2;
r006
DC Bus Volts
Actual DC-link voltage value
Display quantity for the PMU and OP.
6Hex
Analog output: 100 % with code number (PWE) = 4*P071
Type=I2;
r010
AFE utilization
Thermal AFE utilization as a result of an I2t calculation of the
AHex
output current.
Loading the AFE with maximum current for
30 seconds activates an alarm (P622) and for
60 seconds to a reduction in the load current to 91 % of
AFE rated current.
Analog output: 100 % with code number (PWE) = 16384 %
Type=O2;
12-2
(H)
(A)
PKW: 1HEX=1
PZD Gr.: 0
PKW: 1HEX=0.1 A
PZD Gr.: 6
PKW: 1HEX=1 V
PZD Gr.: 7
PKW: 1HEX=1 %
PZD Group: 0
Range
[Unit]
Value Texts
MLFB Input
Init. MLFB
H/W Init
System Init
H/W Setting
System Set.
Fault
ON locked
Rdy ON
Precharging
Rdy Run
Operation
Capacitor
forming
Download
[A]
[V]
[%]
6SE7087-6CX86-2BA1
Operating Instructions SIMOVERT MASTERDRIVES AFE
01.2004
# of Indices
read:
_/_
Factory
write:
_/_
Settings
1 /UHABR
2 /UHABR
2 / BR
2 / BR
2 / BR
Siemens AG

Advertisement

Table of Contents
loading

Table of Contents