Brother DCP-L8400CDN Service Manual page 73

Color laser
Hide thumbs Also See for DCP-L8400CDN:
Table of Contents

Advertisement

Error code 0800
Print Unable 08
Turn the power off and then back on again.
Error occurred in the internal temperature sensor.
Step
1
Connection failure of the internal
temperature sensor harness
2
Main PCB failure
Error code 0900
Print Unable 09
Turn the power off and then back on again.
Machine detected more than 100 times that supplied power was unstable.
< User Check >
- Turn OFF the power switch. After several seconds, turn ON the power again and check that
this error is reset.
Step
1
Low-voltage power supply PCB
failure
2
Main PCB failure
Note:
The irregular power supply detection error (Error code 0900) of the low-voltage power
supply PCB unit occurs when there is a large distortion in the power supply voltage supplied
to the machine. In this case, if the same power supply is used, the same error might occur
again even if the low-voltage power supply PCB unit is replaced.
For this reason, be sure to ask the user to rearrange the installation environment.
Error code 0A01
Print Unable 0A
Turn the power off and then back on again.
The blower failure was detected.
Step
1
Connection failure of the blower
harness
2
Connection failure of the
high-voltage power supply PCB
harness
3
Blower failure
4
Low-voltage power supply PCB
failure
5
High-voltage power supply PCB
failure
6
Main PCB failure
Cause
Reconnect the internal temperature
sensor harness.
Replace the main PCB ASSY.
Cause
Replace the low-voltage power supply
PCB unit. After replacing the low-voltage
power supply PCB unit, refer to
Reset counters for parts (Function code
88)" in Chapter
power supply detection counter of the
low-voltage power supply PCB unit.
Replace the main PCB ASSY.
Cause
Reconnect the blower harness.
Reconnect the high-voltage power supply
PCB harness.
Replace the blower.
Replace the low-voltage power supply
PCB unit.
Replace the high-voltage power supply
PCB ASSY.
Replace the main PCB ASSY.
2-43
Remedy
Remedy
"1.3.37
5, and reset the irregular
Remedy
Confidential

Advertisement

Table of Contents
loading

Table of Contents