3. 8 FIXTURE SETTINGS

It is possible to change the parameter value in the following way:
DIMMER
Enter in Dimmer mode to select specific dimming curve, press the button MENU so many times until
shows DIM MODE, and press the button ENTER to confirm.
Press the button UP/DOWN to select OFF - DIM1 - DIM2 - DIM3.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.

LED FREQUENCY

• To adjust the frequency of the LEDs, press the MENU button repeatedly until the display shows LED
Frequency, and then press the ENTER button.
• Select the frequency (600Hz - 1200Hz - 2000Hz - 4000Hz - 6000Hz - 25kHz) using the UP/DOWN buttons.
• To confirm, press the ENTER key.
• Press the MENU button to go back or wait a few seconds to exit the setup menu.
FAN MODE
• Select this function to set the fans operation mode. Use the arrow buttons to select Auto, On, Off, Silent.
Press the ENTER button to confirm your choice

FACTORY RELOAD

Select this function to reset the unit to the factory settings:
- To activate Reset Factory display press the button MENU so many times until shows Factory Reload, and
press the button ENTER to confirm.
• Press ENTER button to confirm the selection.
• Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.

3. 9 FIXTURE INFORMATION

To view all the information on the device, proceed as follows:
• Press the MENU button to access the main menu.
• Press the UP/DOWN button to scroll the menu, select the icon Information, then press the ENTER but-
ton to enter the next menu.
• Press the UP/DOWN button to scroll through the menu, then select one of the following information
and press the ENTER button to display it.
- Fixture Hours - Through the Fixture Time function you can display the operating time of the projector.
- Software Version - Through Version function you can display the currently installed software version.
- UID - This option shows the RDM identification number
• Press the MENU button repeatedly to exit the menu.

3. 10 OPERATIONS IN AUTOMATIC MODE

MASTER SLAVE
Press the UP/DOWN button to scroll through the menu, select Master/Slave and press ENTER to confirm your
choice.
• Press the UP/DOWN button to select the mode of operation:
- Master, if the unit is connected in series with other units and it acts as the Master;
- Slave, if the unit is not connected to other units.
• Press the ENTER button to confirm your choice.