330 w linear soft cyc and flood light with rgb + warm white colour mixing (45 pages)
Summary of Contents for ProLights EclFresnel CT+M
Page 1
EclFresnel CT+M EclFresnel CT+MIP 350W 6 colours LED Fresnel with 9,4°-80,8° zoom USER MANUAL English version REV.01-10/23-PRELIMINARY...
Page 2
PROLIGHTS product are trademarks OWNED or licensed by Music & Lights S.r.l., its affiliates, and subsidiaries. PROLIGHTS is a registered trademark by Music & Lights S.r.l. All right reserved. Music & Lights – Via A. Olivetti, snc - 04026 - Minturno (LT) ITALY.
• Do not reapply power until repairs have been completed. • Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIGHTS service center. Installation •...
Page 5
• Warning! Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling. • Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture. • Users may carry out external cleaning, following the warnings and instructions pro- vided, but any service operation not described in this manual must be referred to a qualified service technician.
Page 6
• Do not operate the fixture if the ambient temperature (Ta) is below -20 °C (-4 °F). Temperature of the external surface T 80°C • The surface of the fixture can reach up to 80 °C (176 °F) during operation. Avoid contact with people and materials. PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Do not use any type of clamp that does not completely encircle the structure when fastened. RSR0630A/B RSR0630A/B RSR0630A/B steel security cable steel security cable steel security cable C6040 C6002 clamp C6040 clamp clamp 284 mm [11.2 in] Ø13 mm [Ø0.5 in] 80 mm [3.1 in] Fig. 03 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
• The product is then ready for its operations and can be controlled through the available input sig- nals on board. • To disconnect power from the product, disconnect the Mains from the socket. PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
... . DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX512 Controller Fig. 06 - Example 17 DMX channels configuration PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
2. Reach the addressing menu, then select the DMX ADDRESS settings. 3. Select the address from 1 to 512 using the navigation arrows/buttons and confirm by pressing ENTER. 4. Press Menu to exit and return to the Home screen. PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
6. UP: browse upwards through the menu list and increases the numeric value displayed; 7. DOWN: browse downwards through the menu list and decreases the numeric value displayed; 8. PUSHABLE ENCODERS: used to control stand alone modes. PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
TX In TX CRMX Mode Universe first 16 characters of Name Model Name CRMX status Refer to status register on SPI Software Refer to software version Version CRMX Refer to CRMX module Module PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 19
Preset Mode Color Correction Standalone Blackout Emergency Startup Set the behaviour when Hold Behaviour fixture is powered on Hold - On Encoder CCT Mode without any signal Touch; RGB Mode HSI Mode XY Mode PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 20
RGB Mode HSI Mode XY Mode Gel Mode Preset Mode Color Correction INFORMATION Fixture Hours <99999h> <99999h> Source Hours <99999> Power Cycles Real time Informations. Power Consumption Fan Speed Temperatures LED Temperature CPU Temperature PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 21
Voltages U 48V U 12V U 5V Calibration State Error messages Software Version CRMX Module RDM Id Documentation PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
M30 - CCT + XY + GEL 16 bit + CC NOTE: The dmx modes marked with an asterisk (*) are only available if the Colour Correction mode is activated from the menu PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 24
CCT Fine Blue White Point CCT Crossfade from CCT Range White Point CCT CCT to RGB Selector FINE Strobe Strobe Green Control Control Blue Preset Preset Strobe Fan Control Fan Control Control RESERVED RESERVED PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 25
White Point CCT White Point CCT RESERVED Preset Preset Fine Fine Fan Control Fan Control Transition Type Transition Type RESERVED RESERVED Strobe Strobe Control Control Preset Preset Fan Control Fan Control RESERVED RESERVED PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 26
Fan Control Transition Type Control CCT Range Selec- RESERVED Strobe Preset White Point CCT Control Fan Control White Point CCT Preset RESERVED Fine Transition Type Fan Control Strobe RESERVED Control Preset Fan Control RESERVED PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 37
Default @ 128 (8bit) / 32768 (16bit) Full Minus Green 1023 Linear tint correction from -0.025 to +0.025 -99% to -1% 1024 32511 Neutral / No Effect 32512 33023 1% to 99% 33024 65023 Full Plus Green 65024 65535 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 38
Note From From Blue Fine 65535 Default @ 255 (8bit) / 65535 (16bit) Cyan 8 bit value 16 bit value Function Note From From Cyan 65535 Default @ 255 (8bit) / 65535 (16bit) PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 39
From From Amber 65535 Default @ 255 (8bit) / 65535 (16bit) Amber Fine 8 bit value 16 bit value Function Note From From Amber Fine 65535 Default @ 255 (8bit) / 65535 (16bit) PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 42
Note From From LEE: Color cor- Default @ 0 rection LEE:Color Filters LEE: 600 Series LEE: Cosmetic Filters LEE: 700 Series RC: Color cor- rection RC: CalC RC: StSelect RC: C-Lux Blackout Reserved PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 43
LEE Fluorescent 3600 Kelvin LEE Plus Green 1/2 Plus Green 1/4 Plus Green 1/8 Plus Green Lee Minus Green 1/2 Minus Green 1/4 Minus Green 1/8 Minus Green Blackout Reserved for Future Use PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 44
Yellow Light Amber Straw Deep Amber Primary Red Light Rose English Rose Light Salmon Middle Rose Dark Pink Magenta Peacock Blue Steel Blue Light Blue Deep Blue LEE Green Fern Green Dark Green PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 45
Daylight Blue Lilac Tint Deep Lavender Dark Steel Blue Loving Amber Dark Lavender Light Red Flesh Pink Surprise Pink Zenith Blue True Blue Alice Blue Palace Blue Regal Blue Blackout Reserved for Future Use PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 46
Lily Frost Shanklin Frost Half Shanklin Frost Durham Daylight Frost Hampshire Rose Soft Amber Key 1 Soft Amber Key 2 Moroccan Frost Blue Diffusion Blue Frost Daylight Blue Frost Blackout Reserved for Future Use PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 47
Brown Easy White Seedy Pink Wheat Sun Colour Straw LEE Yellow Cardbox Amber Nectarine Millenium Gold Bastard Pink Terry Red Blood Red Moroccan Pink Pretty n'Pink Magical Magenta Blackout Reserved for Future Use PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 50
Orange Henny Sky Light Red No Color Pink Blush Pink Flesh Pink Pale Rose Pink Salmon Deep Salmon Middle Rose Light Rose Purple Surprise Pink No Color Blue Clearwater Booster Blue Tipton Blue PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 51
Default @ 93 (8bit) / 23810 (16bit) 0.8500 Crossfade - Layer 1 to Layer 2 8 bit value 16 bit value Function Note From From Linear, Layer 1 to 65535 Default @ 0 Layer 2 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 52
From From Open Default @ 0 Strobe from Slow to Fast Open Pulse In from slow to fast Closed Pulse Out from slow to fast Open Random from slow to fast Open Reserved PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 53
GEL - RC 3408, Base CCT 5600K Preset 24 GEL - Lee 187, Base CCT 3200K Preset 25 GEL - RC 3152, Base CCT 3200K Preset 26 GEL - Lee 162, Base CCT 3200K Reserved PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 54
Dimmer Speed Off Reserved for future Dimmer Curve Linear Dimmer Curve S-Curve Dimmer Curve Square Law Dimmer Curve Inv. Square Law Dimmer Curve High Res @ Low Reserved for future Tungsten Emula- tion On PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 55
Last Frame Signal Fault On Encoder Touch - CCT mode Signal Fault On Encoder Touch - RGBW mode Reserved for future Signal Fault StandAlone mode Signal Fault Blackout Signal Fault Emergency Reserved for future PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 56
Power Limit 25% Reserved for future Backlight Timeout Always On Backlight Timeout Backlight Timeout Backlight Timeout Backlight Dimmer Backlight Dimmer Backlight Dimmer Backlight Dimmer 100% Flip Display On Flip Display Off Keylock On Keylock Off PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 57
Linear Correction from Cooler to Warmer Desaturate / Saturate 8 bit value 16 bit value Function Note From From Default @ 128 Desaturate/Saturate Linear change from a less saturated light to a more saturated light PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 58
Linear change from less Cyan to more Cyan as you move through x-y coordinates Color Correction: Subtractive Color Mode Default @ 128 ±Cyan Linear change from less red to more red by varying the emission of the Cyan LEDs PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Page 59
Linear change from less Yellow to more Yellow as you move through x-y coordinates Color Correction: Subtractive Color Mode Default @ 128 ±Amber Linear change from less red to more red by varying the emission of the Amber LEDs PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Press the pin (1) and the snap will automatically open upwards (2). Insert the gel filter frame (3) into the gel frame lock (DETAIL) and close down the snap. NOTE: To remove the accessory, reverse the procedure. Fig. 09 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
Press the pin (1) and the snap will automatically open upwards (2). Insert the barn door (3) into the gel frame lock (DETAIL-1) throught the holder assembly of the barn door (DETAIL-2). Then close down the snap. NOTE: To remove the accessory, reverse the procedure. Fig.10 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
SLIDING BRACKET MOVEMENT Pull the clip (1) and the bracket will be free to move (2). once the position of the bracket has been chosen, block the movement by closing the clip (3) Fig. 11 PROLIGHTS - EclFresnel CT+M / EclFresnel CT+MIP...
WARNING: the use of alcohol or any other detergent could damage the lenses. • All other service operations on the product must be carried out by PROLIGHTS, its approved service agents or trained and qualified personnel.
• Check if the Fuse is intact and eventually replace it if fault. necessary. • Contact the PROLIGHTS Service or authorized service partner. Do not remove parts and/or covers, or carry out any repairs or service that are not described in...
Need help?
Do you have a question about the EclFresnel CT+M and is the answer not in the manual?
Questions and answers