Avaya 8600 Configuration Manual page 78

Ethernet routing switch
Hide thumbs Also See for 8600:
Table of Contents

Advertisement

MLT and SMLT link aggregation configuration using Enterprise Device Manager
Prerequisites
• If the port is configured as MLT or MLT-based SMLT, you cannot configure a single port
SMLT.
Procedure steps
1. On the Device Physical View, select a port.
2. In the navigation tree, open the following folders: Configuration > Edit > Port.
3. Click General.
4. Click the SMLT tab.
5. Click Insert.
6. In the SmltId dialog box, enter an unused SMLT ID number.
7. Click Insert.
8. Click Ok.
Variable definitions
Use the data in the following table to help you configure the SmltId dialog box.
Variable
Port
MltId
78
Configuration — Link Aggregation, MLT, and SMLT
Important:
The SMLT tab indicates if this port is configured as MLT or MLT-based SMLT. If
so, you cannot configure a Single Port SMLT.
A warning message appears, informing you that the STP has been disabled while
configuring the port with SMLT.
The SMLT ID is entered.
The slot/port number of the port.
The MLT ID.
• A value of 1–128 indicates that the port is part of an MLT, and
Single Port SMLT cannot be configured on this port.
• A value of 0 indicates that no MLT is assigned, and the port
can be configured for Single Port SMLT.
Comments? infodev@avaya.com
Value
January 2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

8800

Table of Contents