5-8 Selecting the Interruption Mode

This parameter is used to specify the interruption mode when the STOP
command is input.
The Inverter either decelerates or coasts to a stop according to the inter-
ruption mode selection.
Selecting the Interruption Mode (n04)
Interruption Mode Selection
n04
Setting
0, 1
range
Set Values
Value
0
Frequency deceleration stop (see note)
1
Free running
Note The Inverter will decelerate to stop according to the setting in n17 for deceleration
time 1 if any of the n36 through n39 parameters for multi-function input is not set to
11 for acceleration/deceleration time selection. If any one of the n36 through n39
multi-function input parameters is set to acceleration/deceleration time selection,
the Inverter will decelerate to stop according to the selected setting of decelera-
tion time when the STOP command is input.
5-18
Unit of
1
setting
Description
Chapter 5
Changes during
No
operation
Default setting
0