Slip Compensation Function - Omron SYSDRIVE 3G3JV Series User Manual

Compact simplified inverter
Hide thumbs Also See for SYSDRIVE 3G3JV Series:
Table of Contents

Advertisement

Advanced Operation

6-6 Slip Compensation Function

The slip compensation function calculates the motor torque according to
the output current, and sets gain to compensate for output frequency.
This function is used to improve speed accuracy when operating with a
load.
Rated Motor Slip
n64
Setting
0.0 to 20.0 (Hz)
range
Note The default setting varies with the capacity of the Inverter model.
Set Values
Set the rated slip value of the motor in use.
This parameter is used as a slip compensation constant.
Calculate the rated motor slip value from the rated frequency (Hz) and rpm on the mo-
tor nameplate by using the following formula.
Rated slit value (Hz)
Motor Current with No Load
n65
Setting
0 to 99 (%)
range
Note The default setting varies with the capacity of the Inverter model.
Set Values
Set the motor current with no load in percentage based on the rated motor current as
100%.
Contact the motor manufacturer for the motor current with no load.
This parameter is used as a slip compensation constant.
6-12
Unit of
0.1 Hz
setting
Rated frequency (Hz) –
Unit of
1%
setting
Chapter 6
Changes during
operation
Default setting
Rated rpm
Number of poles
120
Changes during
operation
Default setting
Yes
(see note)
No
(see note)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents