Design

2-2-6 Conforming to EC Directive

The following description provides the wiring method of the Inverter to
meet DC Directive requirements. If the following requirements are not sa-
tisfied, the whole equipment incorporating the Inverter will need further
confirmation.
Standard Connection
Main Circuit Terminals
Line breakers
3-phase 200 VAC or
single-phase 200 VAC
Control Circuit Terminals
Forward/Stop
Multi-function input 1 (S2)
Multi-function input 2 (S3)
Multi-function input 3 (S4)
Multi-function input 4 (S5)
Sequence input common
Frequency reference power
supply at +12 V
Frequency reference input
FREQ
adjuster
Frequency reference common
Note I/O signals can be connected to a single shielded cable.
2-32
Noise Filter
Chapter 2
Clamp core
Multi-function contact output
NO
NC
Common
Analog-monitor output
Analog monitor output common