List of Parameters
Pa-
Name
rame-
ter
No.
n52
DC control
current
n53
Interruption DC
control time
n54
Startup DC
control time
n55
Stall prevention
during
deceleration
n56
Stall prevention
level during
acceleration
n57
Stall prevention
level during
operation
n58
Frequency
detection level
n59
Overtorque
detection function
selection
n60
Overtorque
detection level
n61
Overtorque
detection time
9-10
Description
Used to impose DC on the induction motor
for braking control.
Set the DC braking current in percentage
g
based on the rated current of the Inverter
based on the rated current of the Inverter
as 100%.
Output
frequency
frequency
Minimum
output
frequency
(n14)
n54
Used to select a function to change the
deceleration time of the motor
automatically so that there will be no
overvoltage imposed on the motor during
deceleration.
0: Stall prevention during deceleration
enabled
1: Stall prevention during deceleration
disabled
Used to select a function to stop the
acceleration of the motor automatically for
stall prevention during acceleration.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to select a function to reduce the
output frequency of the Inverter
automatically for stall prevention during
operation.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the frequency to be detected.
Note The parameter n40 for multi-function
output must be set for the output of
frequency detection levels 1 and 2.
Used to enable or disable overtorque
detection and select the processing
method after overtorque detection.
0: Overtorque detection disabled
1: Overtorque detection only when speed
coincides and operation continues
(issues alarm)
2: Overtorque detection only when speed
coincides and output shut off (for
protection)
3: Overtorque always detected and
operation continues (issues alarm)
4: Overtorque always detected and output
shut off (for protection)
Used to set overtorque detection level.
Set the level in percentage based on the
rated current of the Inverter as 100%.
Used to set the detection time of
overtorque.
Set-
Unit
ting
of set-
range
ting
0 to
1%
100
p
g
0.0 to
0.1 s
25.5
0.0 to
0.1 s
25.5
Time
n53
0, 1
1
30 to
1%
200
30 to
1%
200
0.0 to
0.1 Hz
400
0 to 4
1
30 to
1%
200
0.1 to
0.1 s
10.0
Chapter 9
Default
Changes
Refer-
setting
during
ence
opera-
page
tion
50
No
6-5
0.5
No
6-5
0.0
No
6-5
0
No
6-6
170
No
6-7
160
No
6-8
0.0
No
6-20
0
No
6-9
160
No
6-10
0.1
No
6-10