Preparing for Operation and Monitoring

3-1 Nomenclature

Data display
Keys
Appearance
Data display
FREQ adjuster
FREF indicator
FOUT indicator
IOUT indicator
MNTR indicator
F/R indicator
LO/RE indicator
PRGM indicator
3-2
Name
Displays relevant data items, such as frequency
reference, output frequency, and parameter set
values.
Sets the frequency reference within a range
between 0 Hz and the maximum frequency.
The frequency reference can be monitored or set
while this indicator is lit.
The output frequency of the Inverter can be
monitored while this indicator is lit.
The output current of the Inverter can be
monitored while this indicator is lit.
The values set in U01 through U10 are
monitored while this indicator is lit.
The direction of rotation can be selected while
this indicator is lit, when operating the Inverter
with the RUN Key.
The operation of the Inverter through the Digital
Operator or according to the parameters set is
selectable while this indicator is lit.
Note This status of this indicator can be only
monitored while the Inverter is in operation.
Any RUN command input is ignored while
this indicator is lit.
The parameters in n01 through n79 can be set or
monitored while this indicator is lit.
Note While the Inverter is in operation, the pa-
rameters can be only monitored and only
some parameters can be changed. The
RUN command input is ignored while
this indicator is lit.
Chapter 3
Indicators
Setting/Monitor item indicators
FREQ adjuster
Function