Design
Reactor Effects
Harmonics are effectively suppressed when the DC reactor is used with the AC reactor
as shown in the following table.
Harmonics
a
o cs
suppression
i
5th
method
har-
monic
No reactor
65
AC reactor
38
DC reactor
30
DC and AC
28
reactors

2-2-5 Wiring Control Circuit Terminals

A control signal line must be 50 m maximum and separated from power
lines.
The frequency reference must be input into the Inverter through shielded,
twisted-pair wires.
Wiring Sequence I/O Terminals
Wire the sequence input terminals (S1 to S5 and SC) and multi-function contact output
terminals (MA, MB, and MC) as described below.
Wires Used
Wire type
Single wire
Stranded wire
Harmonic generation rate (%)
7th
11th
13th
har-
har-
har-
monic
monic
monic
41
8.5
7.7
14.5
7.4
3.4
13
8.4
5
9.1
7.2
4.1
Wire size
2
0.5 to 1.25 mm
2
0.5 to 0.75 mm
Chapter 2
17th
19th
23rd
har-
har-
har-
monic
monic
monic
4.3
3.1
2.6
3.2
1.9
1.7
4.7
3.2
3.0
3.2
2.4
1.6
Wire to be used
Polyethylene-shielded cable
o yet y e e s e ded cab e
25th
har-
monic
1.8
1.3
2.2
1.4