Ed -1E434, Group 131 Cable; Figure 33. Ed-1E434, Group 131 Cable; Table 0. Ed-1E434, Group 131 Cable Connection (Phase 2) - AT&T System 85 Installation And Test

Release 2 versions 1, 2, 3, and 4. remote module and remote group interface
Hide thumbs Also See for System 85:
Table of Contents

Advertisement

ED -1E434, Group 131 Cable
Install the ED -1E434, Group 131 intracabinet cable(s) (Figure 33) in the TMS/RMI cabinet(s)
as shown in Table O. This cable connects from ES on ZAEY2 of the Group 4 Extended
MAAP Bracket to EXT MAAP I and EXT MAAP 0 on the inside of the connector plate
(845416577) added as described in the "Cable Connector Plates" section. This plate is located
at the fan assembly level.
TABLE 0. ED-1E434, Group 131 Cable Connection (Phase 2)
ORIGINATION
CONNECTOR
DESTINATION
CONNECTOR
ZAE Y2 ,
(Extended
MAAP
Bracket)
E5
Connector
Plate at
Fan Assembly
Level
EXT MAAP
1,0
KS-23008, 17
KS -23008, L4
IA- 24 INCHES
LABEL
252A CABLE
6 PAIR,
24 GAUGE
30
INCHES
Figure 33. ED-1E434, Group 131 Cable
E5
AMP 1-102835-5
COVER 103058-8
COVER 103056-8
Page 48