The MC9007A-1 dip switch options are shown in Table AW.
TABLE AW. MC90007A-1 Dip Switch Options
OPTION
SWITCH
1
2
3
4
5
6
7
8
CLOCK
REFERENCE
Local BCM
0
0
0
0
C
0
Line X
C
0
0
0
0
C
Line Y
0
C
0
0
0
C
Line X
0
0
C
0
0
C
ECHO
TAIL
LENGTH
LINE
X
32
Not used
or 16 ms
0
ms
C
LINE
Y
Not used
or 16 ms
0
32 ms
C