Remote Location Connections; Lcit To Orpi Connections; Figure 65. Orpi To Lcit Connections; Table Ah. Cable Group - AT&T System 85 Installation And Test

Release 2 versions 1, 2, 3, and 4. remote module and remote group interface
Hide thumbs Also See for System 85:
Table of Contents

Advertisement

Remote Location Connections
The remote console is connected to several sources through the remote cross-connect field,
and receives its data from the remotely located ORPI. The alarm leads also come from the
ORPI but must be fanned out if more than one remote console is provided. The remote
console receives its voice from an SN233 located in a remote port carrier. The remote
console receives its power from a remote module control or port cabinet with a power supply.
LCIT to ORPI Connections
Use Table AH to determine the proper cable group. Make the connections between the LCIT
and ORPI using the previously selected cable and Figure 65.
TABLE AH. Cable Group
TO
CENTRAL
LCIT
CABLE GROUP
CABLE
MICRON
LENGTH
E01E434-11
TYPE
(FT)
464
LA2A-B
50
10, 15, 20, 25, 30
40, 50, 75, 100
465
LL2A-B
62.5
LCIT
107 ORPI
9
"
BLUE /2
Y1
RECEIVE
«
I I
>---
I I
3
I I
YO
<
WHITE /1
>- TRANSMIT
3-TYPE
FANOUT
SPLICE
401 TYPE
ATTENUATORS
Figure 65. ORPI to LCIT Connections